Patient‐specific dose estimation for pediatric chest CT
Open Access
- 20 November 2008
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 35 (12) , 5821-5828
Abstract
Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full‐body computer models of seven pediatric patients in the same size/protocol group (weight: ) were created based on the patients’ actual multi‐detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, , 70 or , gantry rotation period, pitch of 1.375, beam collimation, and small body scan field‐of‐view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of (coefficient of variation: 10.8%). Normalized lung dose and heart dose were and , respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage , but large for small organs in the scan coverage (9%–18%) and for partially or indirectly exposed organs (11%–77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: ). Normalized lung dose and heart dose correlated strongly with mid‐chest equivalent diameter (lung: , heart: ); these strong correlation relationships can be used to estimate patient‐specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient‐specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols.Keywords
This publication has 26 references indexed in Scilit:
- Effective dose: a flawed concept that could and should be replacedBritish Journal of Radiology, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Effective dose: a useful concept in diagnostic radiology?Radiation Protection Dosimetry, 2007
- Effective dose: how should it be applied to medical exposures?British Journal of Radiology, 2007
- Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dosePhysics in Medicine & Biology, 2007
- CT dosimetry: getting the best from the adult Cristy phantomRadiation Protection Dosimetry, 2005
- National Conference on Dose Reduction in CT, with an Emphasis on Pediatric PatientsAmerican Journal of Roentgenology, 2003
- Dosimetry for Computed Tomography Examination of ChildrenRadiation Protection Dosimetry, 1996
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987
- Photoelectron Enhancement of the Absorbed Dose from X Rays to Human Bone Marrow: Experimental and Theoretical StudiesBritish Journal of Radiology, 1985