Analysis of intact erythropoietin and novel erythropoiesis‐stimulating protein by capillary electrophoresis‐electrospray‐ion trap mass spectrometry
- 21 May 2008
- journal article
- Published by Wiley in Electrophoresis
- Vol. 29 (10) , 2161-2170
Abstract
Recombinant human erythropoietin (rHuEPO) and novel erythropoiesis‐stimulating protein (NESP) were analyzed by CE‐ESI‐MS using an IT as analyzer. The IT parameters were optimized by direct infusion of solutions of different intact proteins (myoglobin, transferrin, α1‐acid glycoprotein and fetuin) with different degrees of glycosylation (from 0 to 35% w/w). Two physically adsorbed capillary coatings from UltraTol™ Pre‐Coats (low normal (LN) and high reverse (HR)) were evaluated for the separation of rHuEPO and NESP glycoforms by CE‐ESI‐IT‐MS. The results obtained with the neutral LN coating suggest that an IT mass spectrometer enables identification of the main glycoforms of a complex glycoprotein such as rHuEPO. Although LN provided acceptable glycoform resolution for rHuEPO, the separation obtained for NESP was less significant due to the higher microheterogeneity of this glycoprotein. Reproducibility studies confirmed the lack of stability and bleeding of the LN coating, which caused problems with MS detection, such as a dramatic loss of sensitivity and the presence of peaks in the mass spectra corresponding to molecular ions in the coating. In contrast, the cationic HR coating gave faster but poorer glycoform separations due to the presence of an anodal EOF. However, the positive charge of the coating provided enhanced hydrolytic stability, making it more suitable than the LN coating for the on‐line MS coupling.Keywords
This publication has 17 references indexed in Scilit:
- Assessing the instability of the isoelectric focusing patterns of erythropoietin in urineElectrophoresis, 2006
- Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis – electrospray – time‐of‐flight mass spectrometryElectrophoresis, 2006
- Glycoform characterization of intact erythropoietin by capillary electrophoresis‐electrospray‐time of flight‐mass spectrometryElectrophoresis, 2005
- Capillary electrophoresis and matrix‐assisted laser desorption/ionization‐time of flight‐mass spectrometry for analysis of the novel erythropoiesis‐stimulating protein (NESP)Electrophoresis, 2005
- Recombinant Erythropoietin and AnaloguesTherapeutic Drug Monitoring, 2004
- Comparison of different capillary electrophoresis methods for analysis of recombinant erythropoietin glycoformsJournal of Separation Science, 2002
- Two-dimensional electrophoresis of recombinant human erythropoietin: A future method for the European Pharmacopoeia?Proteomics, 2002
- Development and characterization of novel erythropoiesis stimulating protein (NESP)British Journal of Cancer, 2001
- Polymer wall coatings for capillary electrophoresisElectrophoresis, 2001
- Recombinant erythropoietin in urineNature, 2000