The SIMPLE Phase II dark matter search
Authors:
- M. FelizardoMFM. Felizardo
- T. A. GirardTGT. A. Girard
- T. MorlatTMT. Morlat
- A. C. FernandesAFA. C. Fernandes
- A. R. RamosARA. R. Ramos
- J. G. MarquesJMJ. G. Marques
- A. KlingAKA. Kling
- J. PuibassetJPJ. Puibasset
- M. AugusteMAM. Auguste
- D. BoyerDBD. Boyer
- A. CavaillouACA. Cavaillou
- J. PoupeneyJPJ. Poupeney
- 22 April 2014
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review D
- Vol. 89 (7)
Abstract
Phase II of SIMPLE (Superheated Instrument for Massive ParticLe Experiments) searched for astroparticle dark matter using superheated liquid ${\mathrm{C}}_{2}{\mathrm{ClF}}_{5}$ droplet detectors. Each droplet generally requires an energy deposition with linear energy transfer (LET) $$\gtrsim${}150\text{ }\text{ }\mathrm{keV}/$\mu${}\mathrm{m}$ for a liquid-to-gas phase transition, providing an intrinsic rejection against minimum ionizing particles of order ${10}^{$-${}10}$, and reducing the backgrounds to primarily $$\alpha${}$ and neutron-induced recoil events. The droplet phase transition generates a millimetric-sized gas bubble that is recorded by acoustic means. We describe the SIMPLE detectors, their acoustic instrumentation, and the characterizations, signal analysis and data selection, which yield a particle-induced, ``true nucleation'' event detection efficiency of better than 97% at a 95% C.L. The recoil-$$\alpha${}$ event discrimination, determined using detectors first irradiated with neutrons and then doped with alpha emitters, provides a recoil identification of better than 99%; it differs from those of COUPP and PICASSO primarily as a result of their different liquids with lower critical LETs. The science measurements, comprising two shielded arrays of fifteen detectors each and a total exposure of 27.77 kgd, are detailed. Removal of the 1.94 kgd Stage 1 installation period data, which had previously been mistakenly included in the data, reduces the science exposure from 20.18 to 18.24 kgd and provides new contour minima of ${$\sigma${}}_{p}=4.3\ifmmode\times\else\texttimes\fi{}{10}^{$-${}3}\text{ }\text{ }\mathrm{pb}$ at $35\text{ }\text{ }\mathrm{GeV}/{\mathrm{c}}^{2}$ in the spin-dependent sector of astroparticle dark matter\char21{}proton interactions and ${$\sigma${}}_{N}=3.6\ifmmode\times\else\texttimes\fi{}{10}^{$-${}6}\text{ }\text{ }\mathrm{pb}$ at $35\text{ }\text{ }\mathrm{GeV}/{\mathrm{c}}^{2}$ in the spin-independent sector. These results are examined with respect to the fluorine spin and halo parameters used in the previous data analysis.
Keywords
All Related Versions
This publication has 67 references indexed in Scilit:
- First dark matter search results from a 4-kgbubble chamber operated in a deep underground sitePhysical Review D, 2012
- Girardet al.(for the SIMPLE Collaboration) Reply:Physical Review Letters, 2012
- Comment on “First Results of the Phase II SIMPLE Dark Matter Search”Physical Review Letters, 2012
- Final Analysis and Results of the Phase II SIMPLE Dark Matter SearchPhysical Review Letters, 2012
- Constraints on low-mass WIMP interactions on 19F from PICASSOPhysics Letters B, 2012
- First Results of the Phase II SIMPLE Dark Matter SearchPhysical Review Letters, 2010
- Improved acoustic instrumentation of the SIMPLE detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- The role of additives towards increasing the SIMPLE SDD lifetimeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Prospects for SIMPLE 2000: a large-mass, low-background superheated droplet detector for WIMP searchesNew Journal of Physics, 2000
- On the Theory of the Bubble ChamberThe Physics of Fluids, 1958