Uncertainty Quantification of the Decay Gamma Source in Mesh-Based Shutdown Dose Rate Calculations
- 17 October 2022
- journal article
- research article
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 79 (1) , 1-12
Abstract
In fusion energy systems, part of the design effort is dedicated to the assessment of the shutdown dose rate (SDR) due to the decay photons that will be emitted from activated components. Monte Carlo transport codes are often used to obtain the neutron flux distribution in the problem domain. The neutron flux distribution is used in the rigorous 2-step (R2S) workflow to obtain the photon emission density distribution of decaying radionuclides. The photon emission density is then used as an input for a dedicated photon transport step to calculate the SDR. In this paper, the uncertainty of the decay gamma source due to the uncertainty of the neutron flux distribution in the R2S workflow is investigated. A scheme is developed to estimate the uncertainty of the decay gamma source, building on the concept of groupwise transmutation and using standard error propagation techniques. The applicability of the newly developed scheme is then demonstrated on one of the conceptual designs of the fusion nuclear science facility.Keywords
This publication has 12 references indexed in Scilit:
- Neutronics aspects of the FESS-FNSFFusion Engineering and Design, 2018
- The examination of the FNSF maintenance approachFusion Engineering and Design, 2018
- Transmutation Approximations for the Application of Hybrid Monte Carlo/Deterministic Neutron Transport to Shutdown Dose Rate AnalysisNuclear Science and Engineering, 2017
- FISPACT-II: An Advanced Simulation System for Activation, Transmutation and Material ModellingNuclear Data Sheets, 2017
- On-the-fly Estimation Strategy for Uncertainty Propagation in Two-Step Monte Carlo Calculation for Residual Radiation AnalysisNuclear Engineering and Technology, 2016
- The Fusion Nuclear Science Facility, the Critical Step in the Pathway to Fusion EnergyFusion Science and Technology, 2015
- Verification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributionsFusion Engineering and Design, 2012
- Rigorous mcnp based shutdown dose rate calculations: computational scheme, verification calculations and application to ITERFusion Engineering and Design, 2002
- What must DEMO do?2002
- Validation of the Alara Activation CodeFusion Technology, 1998