Optimization of skin dose usingin‐vivoMOSFETdose measurements in bolus/non‐bolus fraction ratio: AVMATand a 3DCRTstudy

Authors:

Abstract
In‐phantomandin‐vivothree dimensional conformal radiation therapy (3DCRT) and volumetric modulated arc therapy (VMAT) skin doses, measured with and without bolus in a female anthropomorphic phantomRANDOand in patients, were compared against treatment planning system calculated values. A thorough characterization of the metal oxide semiconductor field effect transistor measurement system was performed prior to the measurements in phantoms and patients. Patients with clinical indication for postoperative external radiotherapy were selected. Skin dose showed higher values with 3DCRTtechnique compared withVMAT. The increase in skin dose due to the use of bolus was quantified. It was observed that, in the case ofVMAT, the bolus effect on the skin dose was considerable when compared with 3DCRT. From the point of view of treatment time, bolus cost, and positioning reproducibility, the use of bolus in these situations can be optimized.

This publication has 34 references indexed in Scilit: