Optimization of skin dose usingin‐vivoMOSFETdose measurements in bolus/non‐bolus fraction ratio: AVMATand a 3DCRTstudy
Open Access
- 9 January 2019
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (2) , 63-70
Abstract
In‐phantomandin‐vivothree dimensional conformal radiation therapy (3DCRT) and volumetric modulated arc therapy (VMAT) skin doses, measured with and without bolus in a female anthropomorphic phantomRANDOand in patients, were compared against treatment planning system calculated values. A thorough characterization of the metal oxide semiconductor field effect transistor measurement system was performed prior to the measurements in phantoms and patients. Patients with clinical indication for postoperative external radiotherapy were selected. Skin dose showed higher values with 3DCRTtechnique compared withVMAT. The increase in skin dose due to the use of bolus was quantified. It was observed that, in the case ofVMAT, the bolus effect on the skin dose was considerable when compared with 3DCRT. From the point of view of treatment time, bolus cost, and positioning reproducibility, the use of bolus in these situations can be optimized.Keywords
This publication has 34 references indexed in Scilit:
- Measurement of skin and target dose in post-mastectomy radiotherapy using 4 and 6 MV photon beamsRadiation Oncology, 2013
- Integration method of 3D MR spectroscopy into treatment planning system for glioblastoma IMRT dose painting with integrated simultaneous boostRadiation Oncology, 2013
- Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapyApplied Radiation and Isotopes, 2009
- Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapyJournal of Experimental & Clinical Cancer Research, 2009
- Whole brain radiotherapy with radiosensitizer for brain metastasesJournal of Experimental & Clinical Cancer Research, 2009
- Assessment of skin dose for breast chest wall radiotherapy as a function of bolus materialPhysics in Medicine & Biology, 2008
- Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning systemJournal of Applied Clinical Medical Physics, 2008
- Radiation Dose to the Female Breast from 16-MDCT Body ProtocolsAmerican Journal of Roentgenology, 2006
- Evaluation of a dual bias dual metal oxide‐silicon semiconductor field effect transistor detector as radiation dosimeterMedical Physics, 1994
- Radiation Tolerance of the SkinActa Radiologica: Therapy, Physics, Biology, 1969