The Effects of Varying Inflation and Deflation Pressures on the Maximal Expiratory Deflation Flow-Volume Relationship in Anesthetized Rhesus Monkeys

Authors:
  • CNChristopher J. L. Newth
    Christopher J. L. Newth
  • BABeat Amsler
    Beat Amsler
  • GAGary P. Anderson
    Gary P. Anderson
  • JMJohn Morley
    John Morley

Abstract
Deflation flow-volume curve analysis is a pulmonary function test sensitive to small airways dysfunction that is suitable for use in infants and children who are intubated. This test relies upon deflation flow-volume (DFV) curve analysis, which is a technique to obtain maximal expiratory flow-volume curves (MEFV) by forced deflation of the lungs in infants who are intubated. The method mimics the voluntary forced flow-volume curves that adults and older children undertake. We studied 10 anesthetized male Rhesus monkeys of the same weight as human infants but developmentally equivalent to older children. We reviewed the effects on forced deflation vital capacity (DVC) and flows at various subdivisions of vital capacity (PEF, MEF50, MEF25, MEF10) of systematically varying the required inspiratory and deflation pressures during the course of 56 consecutive deflation maneuvers. Inflation pressures of +40 and +50 cm H2O caused a marked but transient bradycardia along with a (probably spurious) short-lasting fall to 89% mean arterial oxygen saturation (SaO2). Increasing positive and negative pressures increased DVC and expiratory flows. The highest mean DVC was 75.6 ± 1.3 ml/kg, PEF was 128.0 ± 3.5, MEF50 was 85.9 ± 2.2, MEF25 was 74.3 ± 1.9, and MEF10 was 38.5 ± 2.9 ml/kg/s, all obtained at the pressure gradient of 90 cm H2O (+50/−40 cm H2O) at the start of the deflation maneuver. At this gradient, the intraindividual coefficients of variation were: DVC = 0.8%, PEF = 3.1%, MEF50 = 2.2%, MEF25 = 2.1%, MEF10 = 5.4%. Our data indicate that +40 cm H2O is an appropriate compromise for inflation pressure to define TLC without risking a severe drop in cardiac output, and the deflation pressure of −40 cm H2O provides the highest combination of DVC and expiratory flows. The data also demonstrate remarkable reproducibility, especially for DVC and MEF25. Isovolume DFV curves at 100% VC were produced over a range of opening pressure gradients on six of the monkeys and showed that flow-limitation may occur at MEF25 and MEF10 at negative airway pressures at or below −40 and −20 cm H2O, respectively. We examined the trachéal mucosa by flexible fiberoptic bronchoscope before and after 56 consecutive deflation maneuvers. No mucosal damage was observed, and clinically the monkeys recovered without ill effects. We conclude that the DFV curve analysis is a safe, simple, and extremely reproducible technique for airway function testing in monkeys.

This publication has 2 references indexed in Scilit: