Guide to clinical use of electronic portal imaging
Open Access
- 1 March 2000
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 1 (2) , 38-57
Abstract
The Electronic Portal Imaging Device (EPID) provides localization quality images and computer‐aided analysis, which should in principal, replace portal film imaging. Modern EPIDs deliver superior image quality and an array of analysis tools that improve clinical decision making. It has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments. However, in many radiation therapy clinics EPID technology is not in routine clinical use. This low utilization suggests that the capability and potential of the technology alone do not guarantee its full adoption. This paper addresses basic considerations required to facilitate clinical implementation of the EPID technology and gives specific examples of successful implementations. © 2000 American College of Medical Physics.PACS number(s): 87.53.–j, 87.57.–sKeywords
This publication has 100 references indexed in Scilit:
- Pelvic irradiation of the obese patient: A treatment strategy involving megavoltage simulation and intratreatment setup correctionsMedical Physics, 1996
- Assessing radiation and light field congruence with a video based electronic portal imaging deviceMedical Physics, 1996
- Verification of milled two-dimensional photon compensating filters using an electronic portal imaging deviceMedical Physics, 1996
- High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Reproducibility of patient positioning during routine radiotherapy, as assessed by an integrated megavoltage imaging systemRadiotherapy and Oncology, 1995
- A technique of automating compensator design for lung inhomogeneity correction using an electron portal imaging deviceMedical Physics, 1994
- Optimal radiographic magnification for portal imagingMedical Physics, 1994
- The use of on-line image verification to estimate the variation in radiation therapy dose deliveryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Sampling methods for a matrix ionization chamber systemMedical Physics, 1992
- Performance of a prototype fluoroscopic radiotherapy imaging systemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990