Capillary Biosensor for Glutamate
Authors:
- 1 July 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (13) , 2164-2169
Abstract
We have developed and characterized a novel glutamate biosensor which allows biological transduction of glutamate signal during transport of analyte from the sampling site to the detector. This biosensor exploits the high surface-to-volume ratio found in small-diameter fused silica capillaries. Glutamate dehydrogenase (GDH) was attached to the inner surface of a 75 μm i.d. capillary using biotin-avidin chemistry. In the presence of excess nicotinamide adenine dinucleotide (NAD(+)), GDH converts glutamate to α-ketoglutarate while simultaneously reducing NAD(+) to NADH. Detection of NADH was accomplished using laser-induced fluorescence. Perfusion with 30 μM glutamate in the presence of 3 mM NAD(+) resulted in a strong increase in fluorescence, with a response time of 450 ms. This effect was abolished upon exclusion of NAD(+) from the buffer. The limit of detection is 3 μM (S/N = 3), with a linear working range from 3 to 300 μM. Efficiency of the GDH-modified capillary ranged between 20% and 92% and was positively correlated with concentration of glutamate. The effect of linear velocity was also examined and was shown to be indirectly related to efficiency, with maximum response observed at 4.5 cm/min. In summary, we have demonstrated the successful attachment of glutamate dehydrogenase to the inner wall of a small-diameter fused silica capillary while retaining enzymatic activity. The resulting biosensor exhibits characteristics amenable for in vivo applications. Future efforts will be directed toward the incorporation of this biosensor into current technologies, such as capillary electrophoresis and microdialysis.Keywords
This publication has 19 references indexed in Scilit:
- Transparent chitosan derivatives for the immobilization of glutamate dehydrogenaseBiotechnology and Bioengineering, 1994
- Amperometric Biosensors for On-Line Monitoring of Extracellular Glucose and Glutamate in the BrainAnalytical Letters, 1994
- Online peptide mapping by capillary zone electrophoresisAnalytical Chemistry, 1993
- Quantitative microdialysis under transient conditionsAnalytical Chemistry, 1993
- Blockade of glutamate excitotoxicity and its clinical applicationsNeurochemical Research, 1993
- Enzyme packed bed system for the on-line measurement of glucose, glutamate, and lactate in brain microdialyzateAnalytical Chemistry, 1992
- Enzyme-modified carbon-fiber microelectrodes with millisecond response timesJournal of the American Chemical Society, 1991
- A New Enzymatic Cycling Technique for Glutamate Determination in Brain MicrodialysatesJournal of Neurochemistry, 1990
- Microcolumn Separations and the Analysis of Single CellsScience, 1989
- Alkoxy Silanes for the Preparation of Silica Based Stationary Phases with Bonded Polar Functional GroupsJournal of Liquid Chromatography, 1987