Inter- and intra-observer reliability of clinical movement-control tests for marines
Open Access
- 29 December 2012
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 263
Abstract
Background: Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel.Methods: This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed anin-vivoobservation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model.Results: Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain.Conclusions: Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain.Keywords
This publication has 36 references indexed in Scilit:
- Inter-examiner reproducibility of tests for lumbar motor controlBMC Musculoskeletal Disorders, 2011
- Altered breathing patterns during lumbopelvic motor control tests in chronic low back pain: a case–control studyEuropean Spine Journal, 2009
- Movement control tests of the low back; evaluation of the difference between patients with low back pain and healthy controlsBMC Musculoskeletal Disorders, 2008
- A new perspective on risk assessmentPhysical Therapy in Sport, 2008
- Reliability of movement control tests in the lumbar spineBMC Musculoskeletal Disorders, 2007
- Reliability: What is it, and how is it measured?Physiotherapy, 2000
- Military training-related injuries Surveillance, research, and preventionAmerican Journal of Preventive Medicine, 2000
- Who Is at Risk of What?Infection Control & Hospital Epidemiology, 1999
- The mechanical properties of human motor units with special reference to their fatiguability and recruitment thresholdBrain Research, 1977
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960