All‐inside endoscopic semiautomatic running locked stitch technique shows favourable outcomes for acute Achilles tendon ruptures
Authors:
- 5 April 2024
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (6) , 1615-1621
Abstract
Purpose: The safety and reliability of endoscopic Achilles tendon rupture repair are still concerning aspects. This study's aim is to evaluate an all‐inside endoscopic semiautomatic running locked stitch (Endo‐SARLS) technique.Methods: Forty cases with acute Achilles tendon rupture were treated with the all‐inside Endo‐SARLS technique between 2020 and 2021. Under endoscopic control, the proximal tendon stumps were stitched with the running locked method using a semiautomatic flexible suture passer. The threads of the high‐strength suture were grasped through the paratenon subspace and then fixed into calcaneal insertion with a knotless anchor. Magnetic resonance imaging (MRI), surgical time and complications were assessed. Achilles Tendon Total Rupture Score (ATRS), Achilles Tendon Resting Angle (ATRA) and Heel Rise Height Scale (HRHS) were utilised to evaluate final outcomes.Results: The average follow‐up time was 25.4 ± 0.4 (range: 24–32) months. Appropriate tendon regeneration was observed on MRI after 12 months. At the final follow‐up, the median value of ATRS score was 95 (interquartile range: 94, 98). Furthermore, there is no significant difference between the injured and contralateral side in the average ATRA (18.2 ± 1.8 vs. 18.3 ± 1.9°, ns) and median value of HRHS [14.5 (13.3, 15.5) vs. 14.8 (13.5, 15.6) cm, ns]. No infection and nerve injuries were encountered. Thirty‐nine patients reported that they resumed casual sports activity after 6 months. One patient had a slight anchor cut‐out, due to an addition injury, which was removed after 5 months.Conclusions: An all‐inside Endo‐SARLS technique showed promising clinical results for acute Achilles tendon ruptures. This procedure reduces the risk of sural nerve injuries while establishing a reliable connection between the tendon stumps.Level of Evidence: Level IV.Keywords
This publication has 31 references indexed in Scilit:
- Lower re‐rupture rates but higher complication rates following surgical versus conservative treatment of acute achilles tendon ruptures: a systematic review of overlapping meta‐analysesKnee Surgery, Sports Traumatology, Arthroscopy, 2023
- Achilles tendon resting angle is able to detect deficits after an Achilles tendon rupture, but it is not a surrogate for direct measurements of tendon elongation, function or symptomsKnee Surgery, Sports Traumatology, Arthroscopy, 2022
- Intra-operative ultrasound: does it improve the results of percutaneous repair of acute Achilles tendon rupture?European Journal of Trauma and Emergency Surgery, 2022
- The release of adhesions improves outcome following minimally invasive repair of Achilles tendon ruptureKnee Surgery, Sports Traumatology, Arthroscopy, 2021
- Endoscopic “internal splinting” repair technique for acute Achilles tendon ruptureArchives of orthopaedic and trauma surgery, 2021
- Open versus minimally-invasive surgery for Achilles tendon rupture: a meta-analysis studyArchives of orthopaedic and trauma surgery, 2020
- Validity and reliability of the Norwegian translation of the Achilles tendon Total Rupture ScoreKnee Surgery, Sports Traumatology, Arthroscopy, 2017
- Clinical failure after Dresden repair of mid-substance Achilles tendon rupture: human cadaveric testingKnee Surgery, Sports Traumatology, Arthroscopy, 2016
- A new measurement of heel‐rise endurance with the ability to detect functional deficits in patients with Achilles tendon ruptureKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Die perkutane Naht der Achillessehne mit dem Dresdner InstrumentOperative Orthopädie und Traumatologie, 2006