4D flow MRI velocity uncertainty quantification
Open Access
- 13 September 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (1) , 397-410
Abstract
Purpose: An automatic method is presented for estimating 4D flow MRI velocity measurement uncertainty in each voxel. The velocity distance (VD) metric, a statistical distance between the measured velocity and local error distribution, is introduced as a novel measure of 4D flow MRI velocity measurement quality.Methods: The method uses mass conservation to assess the local velocity error variance and the standardized difference of means (SDM) velocity to estimate the velocity error correlations. VD is evaluated as the Mahalanobis distance between the local velocity measurement and the local error distribution. The uncertainty model is validated synthetically and tested in vitro under different flow resolutions and noise levels. The VD's application is demonstrated on two in vivo thoracic vasculature 4D flow datasets.Results: Synthetic results show the proposed uncertainty quantification method is sensitive to aliased regions across various velocity‐to‐noise ratios and assesses velocity error correlations in four‐ and six‐point acquisitions with correlation errors at or under 3.2%. In vitro results demonstrate the method's sensitivity to spatial resolution, venc settings, partial volume effects, and phase wrapping error sources. Applying VD to assess in vivo 4D flow MRI in the aorta demonstrates the expected increase in measured velocity quality with contrast administration and systolic flow.Conclusion: The proposed 4D flow MRI uncertainty quantification method assesses velocity measurement error owing to sources including noise, intravoxel phase dispersion, and velocity aliasing. This method enables rigorous comparison of 4D flow MRI datasets obtained in longitudinal studies, across patient populations, and with different MRI systems.Keywords
Funding Information
- Division of Intramural Research (R01 HL115267, R21 NS106696)
This publication has 38 references indexed in Scilit:
- The impact of 4D flow displacement artifacts on wall shear stress estimationMagnetic Resonance in Medicine, 2021
- Accelerated dual-venc 4D flow MRI for neurovascular applicationsJournal of Magnetic Resonance Imaging, 2017
- Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithmJournal of Magnetic Resonance Imaging, 2015
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- k‐t GRAPPA: A k‐space implementation for dynamic MRI with high reduction factorMagnetic Resonance in Medicine, 2005
- Correction of partial‐volume effects in phase‐contrast flow measurementsJournal of Magnetic Resonance Imaging, 1995
- Understanding acceleration‐induced displacement artifacts in phase‐contrast MR velocity measurementsJournal of Magnetic Resonance Imaging, 1995
- Three‐Point Phase‐Contrast Velocity Measurements with Increased Velocity‐to‐Noise RatioMagnetic Resonance in Medicine, 1995
- Analysis of systematic and random error in MR volumetric flow measurementsMagnetic Resonance in Medicine, 1993
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991