Ophthalmoscopy and Vitreoretinal Surgery in Patients With an ARRAY Refractive Multifocal Intraocular Lens Implant
Authors:
- Martin A MainsterMMMartin A Mainster
- Elias ReichelERElias Reichel
- Keith A WarrenKWKeith A Warren
- Peter G HarringtonPHPeter G Harrington
- 1 January 2002
- journal article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 33 (1) , 74-76
Abstract
We developed a clinical strategy for dealing with situations in which ophthalmoscopic examination and vitreoretinal surgery are difficult in patients with an ARRAY® refractive multifocal intraocular lens (IOL) implant. The ARRAY zonal-progressive IOL has a central 2. 1 -mm distance-vision zone for optically-unobstructed posterior pole observation. A concentric near-vision zone (+3.5-diopter add) surrounds this central zone. Optical ray-tracing is used to determine how a 2.1-mm pupil limitation restricts monocular and binocular retinal image size in head-mounted, slitlamp, and operating microscope ophthalmoscopy. A 2.1-mm pupil decreases the retinal field of view of high magnification, narrow field lenses much more than that of wider-field, lower magnification lenses. This "worst-case" analysis suggests an ophthalmoscopic strategy, but is not strictly valid for the ARRAY lens because the near-vision zone surrounding its 2.1-mm central zone is not opaque. The near-vision zone contributes defocused information to the ophthalmoscopic image, diminishing its resolution and depth information. Wide-field, low magnification lenses are potentially less problematic than higher magnification lenses for examining and treating patients with an ARRAY IOL implant. This strategy is useful for panretinal photocoagulation or photodynamic therapy, but not for procedures requiring high magnification stereoscopic vision such as macular vitreoretinal surgery. [Opthalmic Surg Lasers 2002;33:74-76]Keywords
This publication has 10 references indexed in Scilit:
- Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantationBritish Journal of Ophthalmology, 2000
- Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomesJournal of Cataract & Refractive Surgery, 2000
- Vitreoretinal surgery through multifocal intraocular lenses compared with monofocal intraocular lenses in fluid-filled and air-filled rabbit eyesOphthalmology, 2000
- Visual outcome with the Array multifocal intraocular lens in patients with concurrent eye diseaseJournal of Cataract & Refractive Surgery, 2000
- AMO array multifocal lens versus monofocal correction in cataract surgeryJournal of Cataract & Refractive Surgery, 2000
- Driving simulation study: Bilateral Array multifocal versus bilateral AMO monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 1999
- A prospective comparative study of the amo array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lensOphthalmology, 1999
- Posterior segment visualization problems with multifocal intraocular lensesActa Ophthalmologica Scandinavica, 1996
- A Prospective, Randomized, Double-masked Comparison of a Zonal-Progressive Multifocal Intraocular Lens and a Monofocal Intraocular LensOphthalmology, 1992
- Retinal laser lenses: magnification, spot size, and field of view.British Journal of Ophthalmology, 1990