Design of a new hypoxanthine biosensor: xanthine oxidase modified carbon film and multi-walled carbon nanotube/carbon film electrodes
- 22 December 2012
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (11) , 3813-3822
Abstract
A new and simple-to-prepare hypoxanthine biosensor has been developed using xanthine oxidase (XOD) immobilised on carbon electrode surfaces. XOD was immobilised by glutaraldehyde cross-linking on carbon film (CF) electrodes and on carbon nanotube (CNT) modified CF (CNT/CF). A comparison of the performance of the two configurations was carried out by the current response using amperometry at fixed potential; the best characteristics being exhibited by XOD/CNT/CF modified electrodes. The effects of electrolyte pH and applied potential were evaluated, and a proposal is made for the enzyme mechanism of action involving competition between regeneration of flavin adenine dinucleotide and reduction of hydrogen peroxide. Under optimised conditions, the determination of hypoxanthine was carried out at −0.2 V vs. a saturated calomel electrode (SCE) with a detection limit of 0.75 μM on electrodes with CNT and at −0.3 V vs. SCE with a detection limit of 0.77 μM on electrodes without CNT. The applicability of the biosensor was verified by performing an interference study, reproducibility and stability were investigated, and hypoxanthine was successfully determined in sardine and shrimp samples.Keywords
This publication has 49 references indexed in Scilit:
- Poly(Neutral Red)/Cholesterol Oxidase Modified Carbon Film Electrode for Cholesterol BiosensingElectroanalysis, 2012
- Electrochemical impedance studies of chitosan-modified electrodes for application in electrochemical sensors and biosensorsElectrochimica Acta, 2010
- A Combined QM/MM Study on the Reductive Half-Reaction of Xanthine Oxidase: Substrate Orientation and MechanismJournal of the American Chemical Society, 2009
- Fabrication of an amperometric bienzyme biosensing system with neutral red functionalized carbon nanotubesThe Analyst, 2009
- Poly(neutral red): Electrosynthesis, Characterization, and Application as a Redox MediatorElectroanalysis, 2008
- Voltammetric and impedance studies of inosine-5′-monophosphate and hypoxanthineBioelectrochemistry, 2003
- Amperometric on-line sensor for continuous measurement of hypoxanthine based on osmium-polyvinylpyridine gel polymer and xanthine oxidase bienzyme modified glassy carbon electrodeAnalytica Chimica Acta, 2000
- Biosensor for detection of hypoxanthine based on xanthine oxidase immobilized on chemically modified carbon paste electrodeAnalytica Chimica Acta, 2000
- The effect of glutaraldehyde on the electrochemical behavior of polyanilineElectrochimica Acta, 1999
- Adsorbed and spread films of bovine milk xanthine oxidase at the air–water interfaceColloids and Surfaces A: Physicochemical and Engineering Aspects, 1998