Filtering electrocardiographic signals using an unbiased and normalized adaptive noise reduction system
Authors:
- Yunfeng WuYWYunfeng Wu
- Rangaraj M. RangayyanRRRangaraj M. Rangayyan
- Yachao ZhouYZYachao Zhou
- Sin-Chun NgSNSin-Chun Ng
- 9 May 2008
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 31 (1) , 17-26
Abstract
We present a novel unbiased and normalized adaptive noise reduction (UNANR) system to suppress random noise in electrocardiographic (ECG) signals. The system contains procedures for the removal of baseline wander with a two-stage moving-average filter, comb filtering of power-line interference with an infinite impulse response (IIR) comb filter, an additive white noise generator to test the system's performance in terms of signal-to-noise ratio (SNR), and the UNANR model that is used to estimate the noise which is subtracted from the contaminated ECG signals. The UNANR model does not contain a bias unit, and the coefficients are adaptively updated by using the steepest-descent algorithm. The corresponding adaptation process is designed to minimize the instantaneous error between the estimated signal power and the desired noise-free signal power. The benchmark MIT-BIH arrhythmia database was used to evaluate the performance of the UNANR system with different levels of input noise. The results of adaptive filtering and a study on convergence of the UNANR learning rate demonstrate that the adaptive noise-reduction system that includes the UNANR model can effectively eliminate random noise in ambulatory ECG recordings, leading to a higher SNR improvement than that with the same system using the popular least-mean-square (LMS) filter. The SNR improvement provided by the proposed UNANR system was higher than that provided by the system with the LMS filter, with the input SNR in the range of 5-20 dB over the 48 ambulatory ECG recordings tested.Keywords
Funding Information
- National Natural Science Foundation of China (60575034)
- University of Calgary
- Ministry of Education of the People's Republic of China (20060013007)
- Division of Graduate Studies, University of Oregon
- Beijing University of Posts and Telecommunications
- Croucher Foundation
This publication has 17 references indexed in Scilit:
- A Nonlinear Bayesian Filtering Framework for ECG DenoisingIEEE Transactions on Biomedical Engineering, 2007
- Combining Algorithms in Automatic Detection of QRS Complexes in ECG SignalsIEEE Transactions on Information Technology in Biomedicine, 2006
- PhysioNet: a Web-based resource for the study of physiologic signalsIEEE Engineering in Medicine and Biology Magazine, 2001
- A new method for the extraction of fetal ECG from the composite abdominal signalIEEE Transactions on Biomedical Engineering, 2000
- ECG beat detection using filter banksIEEE Transactions on Biomedical Engineering, 1999
- Artificial neural networks for automatic ECG analysisIEEE Transactions on Signal Processing, 1998
- Fetal ECG extraction from single-channel maternal ECG using singular value decompositionIEEE Transactions on Biomedical Engineering, 1997
- A patient-adaptable ECG beat classifier using a mixture of experts approachIEEE Transactions on Biomedical Engineering, 1997
- A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECGIEEE Transactions on Biomedical Engineering, 1996
- Comparing stress ECG enhancement algorithmsIEEE Engineering in Medicine and Biology Magazine, 1996