Abstract
With the advent of microinvasive glaucoma surgery (MIGS), the spectrum of modalities available to manage patients with this chronic and heterogeneous condition has broadened. Despite its novelty however, there has been a rapid evolution in the development of a multitude of devices, each targeting a structure along the aqueous drainage pathway. A growing body of evidence has demonstrated IOP and medication burden reduction, and a more favorable safety profile with MIGS procedures in contrast to traditional incisional surgeries. Among the array of MIGS, the Hydrus® Microstent (Ivantis, Inc., Irvine, CA) is a recent FDA approved device, designed to bypass the trabecular meshwork and provide a scaffold for Schlemm’s canal. The objective of this article is to review the Hydrus from conception to clinical use, and present data on its efficacy and safety to date. The available literature has shown promise, however inherent to all novel devices, only long-term monitoring will ensure sustained IOP control and an acceptable safety profile. Surgical advancements in glaucoma have revolutionized the field, and continued research and development will establish these approaches in clinical treatment algorithms.Keywords
This publication has 57 references indexed in Scilit:
- A Novel 8-mm Schlemm's Canal Scaffold Reduces Outflow Resistance in a Human Anterior Segment Perfusion ModelInvestigative Ophthalmology & Visual Science, 2013
- Ocular Biocompatibility of Nitinol Intraocular ClipsInvestigative Ophthalmology & Visual Science, 2012
- Prevalence of Ocular Surface Complaints in Patients With Glaucoma Using Topical Intraocular Pressure-Lowering MedicationsCornea, 2010
- A Comparative Biocompatibility Analysis of Ternary Nitinol AlloysJournal of Materials Engineering and Performance, 2009
- The influence of surface oxides on the distribution and release of nickel from Nitinol wiresBiomaterials, 2009
- Prevalence of Ocular Surface Disease in Glaucoma PatientsJournal of Glaucoma, 2008
- Critical overview of Nitinol surfaces and their modifications for medical applicationsActa Biomaterialia, 2008
- Development, implantation, in vivo elution, and retrieval of a biocompatible, sustained release subretinal drug delivery systemJournal of Biomedical Materials Research Part A, 2005
- Selective Laser Trabeculoplasty (SLT) Complicated by Intraocular Pressure Elevation in Eyes With Heavily Pigmented Trabecular MeshworksAmerican Journal of Ophthalmology, 2005
- Histopathologic evaluation of a novel‐design nitinol stent: the Biflex stentInternational Journal of Cardiovascular Interventions, 2004