Outcomes of Direct Flow Medical vs Sapien 3 Transcatheter Aortic Valve Devices
Authors:
- 17 December 2019
- journal article
- research article
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 13 (5) , 790-795
Abstract
This retrospective study was aimed to compare the safety and efficacy of the Direct Flow Medical (DFM) valve with the more established Sapien 3 (S3) valve in transfemoral TAVI in high-risk aortic stenosis (AS) patients. Between February 2014 and August 2016, 99 and 68 patients had the S3 and DFM valves at our center, respectively. The device success rate was statistically similar among the S3 and DFM groups (p = 0.15). The overall post-procedural complication rate was similar between the two groups (p = 0.4). The procedural time was significantly shorter in the S3 group (p < 0.001) and the post-procedure peak pressure gradient (p < 0.001) was significantly higher in the DFM group. However, the frequency of valvular or paravalvular leaks was similar between both valve groups. We found no significant differences in terms of safety between the DFM and S3 valves. This study confirms the safety and efficacy of the DFM valve in high-risk AS patients.Keywords
This publication has 26 references indexed in Scilit:
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus documentThe Journal of Thoracic and Cardiovascular Surgery, 2013
- 2-Year Follow-Up of Patients Undergoing Transcatheter Aortic Valve Implantation Using a Self-Expanding Valve ProsthesisJACC, 2011
- Percutaneous transarterial aortic valve implantation: what do we know?European Heart Journal, 2010
- Incidence and Management of CoreValve Dislocation During Transcatheter Aortic Valve ImplantationCirculation: Cardiovascular Interventions, 2010
- Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve BioprosthesisJACC, 2010
- Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) RegistryCirculation, 2010
- Transcatheter Aortic Valve Implantation for the Treatment of Severe Symptomatic Aortic Stenosis in Patients at Very High or Prohibitive Surgical RiskJACC, 2010
- Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: results from the multicentre, expanded evaluation registry 1-year following CE mark approvalEuroIntervention, 2008
- Treatment of Calcific Aortic Stenosis With the Percutaneous Heart ValveJACC, 2006
- Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosisJACC, 2004