Two‐point dixon fat–water separation: Improving reliability and accuracy in phase correction algorithms
Authors:
- Maria A. SchmidtMSMaria A. Schmidt
- Karlene M. FraserKFKarlene M. Fraser
Open Access
- 11 April 2008
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (5) , 1122-1129
Abstract
Purpose To propose an advanced phase-correction region-growing algorithm for two-point fat–water separation suitable for parotid assessment, and to evaluate the general performance of phase-correction algorithms. Materials and Methods Two region-growing algorithms were evaluated in test objects and in head images: the original phase-correction algorithm (OPC) and the advanced phase-correction algorithm with voxel size manipulation (VSM) which includes: 1) starting the region-growing process from images of lower resolution and subsequently stepping toward the original matrix size, and 2) limiting the use of low-pass filters to fat–water interfaces with partial volume effects Results Fundamental problems relate to biological tissue spectrum being poorly approximated by two discrete peaks for fat and water. The VSM algorithm was shown to be less noise-sensitive, faster, and to produce a better approximation for the field inhomogeneity map. In head images (6 volunteers, 10 slices each) 43 errors were found with the OPC algorithm and only 6 errors with the VSM algorithm. Only the OPC algorithm produced errors surrounding the parotids (10 errors). Conclusion The VSM algorithm provides a more accurate and less noise-sensitive fat–water separation. This highly significant performance improvement allows the application of phase-correction algorithms to a wider range of clinical applications. J. Magn. Reson. Imaging 2008.Keywords
This publication has 15 references indexed in Scilit:
- Field map estimation with a region growing scheme for iterative 3‐point water‐fat decompositionMagnetic Resonance in Medicine, 2005
- Cramér–Rao bounds for three‐point decomposition of water and fatMagnetic Resonance in Medicine, 2005
- Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithmMagnetic Resonance in Medicine, 2004
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Fast, automated, N‐dimensional phase‐unwrapping algorithmMagnetic Resonance in Medicine, 2002
- A three‐point dixon method for water and fat separation using 2D and 3D gradient‐echo techniquesJournal of Magnetic Resonance Imaging, 1998
- Water‐fat imaging with direct phase encodingJournal of Magnetic Resonance Imaging, 1997
- An extended two‐point dixon algorithm for calculating separate water, fat, and B0 imagesMagnetic Resonance in Medicine, 1997
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Simple proton spectroscopic imaging.Radiology, 1984