Management of high-energy tibial shaft fractures using the hexapod circular external fixator
Open Access
- 21 February 2021
- journal article
- research article
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-9
Abstract
Background: The hexapod external fixator (HEF) is increasingly used for high-energy tibial shaft fracture care as more general orthopedic surgeons are gaining expertise of this versatile device. The purpose of this study was to evaluate the clinical effectiveness of the HEF for definitive management in patients with high-energy tibial shaft fractures. Methods: The study was conducted on 34 patients with tibial shaft fractures who were admitted or referred to our institution and consented to HEF treatment from Jan 2016 to June 2019, including 27 males and 7 females with a mean age of 39 years (range 18 to 65 years). Patients' clinical and radiological data, and the final clinical outcomes at a minimum of 12 months follow-up were collected and retrospectively analyzed. All complications were documented according to Paley’s classification. The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit. Results: All patients remained in the HEF for a mean of 26 weeks (range 15 to 52 weeks) and acquired complete bone union. The satisfactory alignment was achieved in all patients, and all the patients were able to perform daily activities with no difficulty at the last clinical visit. Complications included pin tract infection (44%), delayed union (6%), nonunion (3%), and joint stiffness (3%). The ASAMI bony result was excellent in 31 patients and good in 3. The ASAMI functional result was excellent in 27 patients, good in 6, and fair in 1. Conclusions: Definitive management using the hexapod external fixator is an alternative and effective method for high-energy tibial shaft fractures, including technical advantages of early trauma-control, the versatility of achieving excellent alignment, and the continuity of device until bone union.Keywords
All Related Versions
This publication has 38 references indexed in Scilit:
- Intentional Deformation and Closure of Soft Tissue Defect in Open Tibial Fractures With a Taylor Spatial Frame—A Simple TechniqueJournal of Orthopaedic Trauma, 2013
- Posttraumatic Taylor Spatial Frame Deformity Correction in AdultsOperative Techniques in Orthopaedics, 2011
- Bone Transport for Postinfectious Segmental Tibial Bone Defects With a Combined Ilizarov/Taylor Spatial Frame TechniqueJournal of Orthopaedic Trauma, 2011
- Capsuloligamentotaxis and definitive fixation by an ankle-spanning Ilizarov fixator in high-energy pilon fracturesThe Journal of Bone and Joint Surgery. British volume, 2010
- Alternative fixation method for open femoral fractures from a damage control orthopaedics perspectiveInjury, 2010
- Taylor spatial frame in the treatment of open tibial shaft fracturesIndian Journal of Orthopaedics, 2008
- Pin tract infection with external fixation of pediatric fracturesJournal of Pediatric Surgery, 2007
- A comparison of monolateral and circular external fixation of unstable diaphyseal tibial fractures in childrenJournal of Pediatric Orthopaedics B, 2003
- External fixation as a primary and definitive treatment of open limb fracturesInjury, 1995
- Problems, Obstacles, and Complications of Limb Lengthening by the Ilizarov TechniqueClinical Orthopaedics and Related Research, 1990