Abstract
Background: Cardiac resynchronization therapy (CRT) is usually performed with biventricular pacing (BiVP), but recently, conduction system pacing (CSP) has been proposed as an alternative in case of BiVP failure. The aim of this study is to define an algorithm to choose between BiVP and CSP resynchronization using the interventricular conduction delays (IVCD) as a guide. Methods: Consecutive patients from January 2018 to December 2020 with an indication for CRT were prospectively enrolled in the study group (delays-guided resynchronization group, DRG). A treatment algorithm based on IVCD was used to decide whether to leave the left ventricular (LV) lead to perform BiVP or pull it out and perform CSP. Outcomes from the DRG group were compared to a historical cohort of CRT patients who underwent CRT procedures between January 2016 and December 2017 (resynchronization standard guide group, SRG). The primary endpoint was a composite of cardiovascular mortality, heart failure (HF) hospitalization, or HF event at 1 year after the date of intervention. Results: The study population consisted of 292 patients, of which 160 (54.8%) were in the DRG and 132 (45.2%) in the SRG. In the DRG, 41 of 160 patients underwent CSP based on the treatment algorithm (25.6%). The primary endpoint was significantly higher in the SRG (48/132, 36.4%) compared to the DRG (35/160, 21.8%) (hazard ratio (HR): 1.72; 95% confidence interval (CI): 1.12–2.65; p = 0.013). Conclusions: A treatment algorithm based on IVCD shifted one patient out of every four from BiVP to CSP, with consequent reduction in the primary endpoint after implantation. Therefore, its application could be useful to determine whether to perform BiVP or CSP.Keywords
This publication has 20 references indexed in Scilit:
- Avoiding non-responders to cardiac resynchronization therapy: a practical guideEuropean Heart Journal, 2016
- Association of Body Mass Index With Cardiac Reverse Remodeling and Long-Term Outcome in Advanced Heart Failure Patients With Cardiac Resynchronization TherapyCirculation Journal, 2014
- Effect of QRS Duration and Morphology on Cardiac Resynchronization Therapy Outcomes in Mild Heart FailureCirculation, 2012
- Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)Circulation, 2011
- Non-Responders to Cardiac Resynchronization Therapy - The Magnitude of the Problem and the Issues -Circulation Journal, 2011
- Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure EventsNew England Journal of Medicine, 2009
- Randomized Trial of Cardiac Resynchronization in Mildly Symptomatic Heart Failure Patients and in Asymptomatic Patients With Left Ventricular Dysfunction and Previous Heart Failure SymptomsJACC, 2008
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureThe New England journal of medicine, 2005
- Clinical and electrocardiographic predictors of a positive response to cardiac resynchronization therapy in advanced heart failureEuropean Heart Journal, 2005
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureThe New England journal of medicine, 2004