Visualization of deep veins and detection of deep vein thrombosis (DVT) with balanced turbo field echo (b‐TFE) and contrast‐enhanced T1 fast field echo (CE‐FFE) using a blood pool agent (BPA)
Open Access
- 23 January 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (2) , 416-424
Abstract
Purpose: To assess image quality, vessel visualization, preliminary diagnostic properties, and interobserver variability of a novel balanced turbo field echo (b-TFE) sequence and contrast-enhanced T1 fast field echo (CE-FFE) sequence with blood pool agent (BPA). Materials and Methods: A total of 15 healthy volunteers and six patients with ultrasound-verified proximal deep vein thrombosis (DVT) were examined from the inferior vena cava (IVC) to the proximal calf veins. Results: The great majority of deep veins were completely visualized on both sequences. In healthy volunteers the IVC was completely visualized in five b-TFE and 11 CE-FFE scans, and partially in seven b-TFE and four CE-FFE scans (P = 0.008). Poorest image quality was in the pelvis. Contrast-to-noise ratio (CNR) was higher on b-TFE compared to CE-FFE, with significant difference in calf images (P = 0.036). Sensitivity was 100% for proximal DVT with both methods. Specificity was 70% (CE-FFE) and 80% (b-TFE) for proximal femoral DVT; 100% in distal femoral. Interobserver reliability was kappa 1.0 (b-TFE), 0.9 (CE-FFE) for proximal, and overall poor for distal DVT. Conclusion: Contrast-enhancement did not add valuable information in visualizing deep veins of the lower limbs compared to b-TFE, though the IVC was slightly better visualized. Diagnostic properties and interobserver reliability of both sequences were good for proximal DVT and poor for distal DVT. J. Magn. Reson. Imaging 2010; 31: 416–424.Keywords
This publication has 20 references indexed in Scilit:
- Magnetic resonance direct thrombus imaging of the evolution of acute deep vein thrombosis of the legJournal of Thrombosis and Haemostasis, 2008
- Magnetic resonance portal venography: use of fast-acquisition true FISP imaging in the detection of portal vein thrombosisClinical Radiology, 2007
- Three-Dimensional Breathhold Magnetization-Prepared TrueFISPInvestigative Radiology, 2007
- Maximizing contrast‐to‐noise ratio in ultra‐high resolution peripheral MR angiography using a blood pool agent and parallel imagingJournal of Magnetic Resonance Imaging, 2007
- Intravascular hematocrit layering in equilibrium phase contrast‐enhanced MR angiography of the peripheral vasculatureJournal of Magnetic Resonance Imaging, 2006
- MR Venography with True Fast Imaging with Steady-state Precession for Suspected Lowerlimb Deep Vein ThrombosisJournal of Vascular and Interventional Radiology, 2006
- Is True FISP Imaging Reliable in the Evaluation of Venous Thrombosis?American Journal of Roentgenology, 2005
- Fat‐suppressed steady‐state free precession imaging using phase detectionMagnetic Resonance in Medicine, 2003
- MR-Venography Using High Resolution True-FISPRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999