Magnetometer Utilizing Cooled Normal Pickup Coil and High-TcSuperconducting Quantum Interference Device Picovoltmeter for Nondestructive Evaluation
Authors:
- Tong Qing YangTYTong Qing Yang
- Kenichiro YaoKYKenichiro Yao
- Daisuke YamasakiDYDaisuke Yamasaki
- Keiji EnpukuKEKeiji Enpuku
- 1 May 2005
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 44 (5L) , L626
Abstract
A magnetometer utilizing a cooled normal pickup coil and a high-Tcsuperconducting quantum interference device (SQUID) picovoltmeter was applied to nondestructive evaluation in an unshielded environment. The pickup coil of copper wire was cooled toT=77 K in order to decrease thermal noise from resistance. The magnetic field noise of the magnetometer was 130 pT/Hz1/2and 10 pT/Hz1/2at 100 Hz and 1 kHz, respectively, for the pickup coil with a 4.4 mm diameter. It was shown that the magnetometer could be moved in an unshielded environment without degradation of its performance. By moving the cooled pickup coil, we successfully detected a small crack on the backsurface of the Cu plate in an unshielded environment.Keywords
This publication has 10 references indexed in Scilit:
- A high-TcSQUID gradiometer with integrated homogeneous field compensationSuperconductor Science and Technology, 2004
- Mobile HTS rf SQUID magnetometerIEEE Transactions on Applied Superconductivity, 2003
- High Tc Superconducting Quantum Interference Device Magnetometer Utilizing Cooled Copper Pickup Coil and Resonant Coupling CircuitJapanese Journal of Applied Physics, 2002
- Recent developments in SQUID NDEPhysica C: Superconductivity and its Applications, 2002
- Specific heat in the superconducting and normal state (2–300 K, 0–16 T), and magnetic susceptibility of the 38 K superconductor MgB2: evidence for a multicomponent gapPhysica C: Superconductivity and its Applications, 2001
- Detection of deep flaws by using a HTS-SQUID in unshielded environmentIEEE Transactions on Applied Superconductivity, 2001
- High-T/sub c/ SQUID gradiometer for mobile magnetic anomaly detectionIEEE Transactions on Applied Superconductivity, 2001
- Electronic gradiometer using HT/sub c/ SQUIDs with fast feedback electronicsIEEE Transactions on Applied Superconductivity, 2001
- Compensation electronics for larger dynamic range of a SQUID based nondestructive evaluation systemReview of Scientific Instruments, 1999
- Experiments on eddy current NDE with HTS rf SQUIDSIEEE Transactions on Applied Superconductivity, 1997