Quantitative ultrashort TE imaging of the short‐T2 components in skeletal muscle using an extended echo‐subtraction method
- 3 October 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (3) , 997-1008
Abstract
Purpose: To introduce an ultrashort echo time (UTE) based method for quantitative mapping of short‐T2 signals in skeletal muscle (SKM) in the presence of fat, with the aim of monitoring SKM fibrosis.Methods: From a set of at least five UTE images of the same slice, a long‐ map, a fat‐fraction map, and a map of short‐T2‐signal fraction are extracted. The method was validated by numerical simulations and in vitro studies on collagen solutions. Finaly, the method was applied to image the short‐T2 signals in the leg of eight healthy volunteers.Results: The imaged short‐T2‐signal fractions in the collagen solutions correlated with their respective collagen concentrations ( ). Short‐T2 tissues such as cortical bone and fasciae were highlighted in the resulting short‐T2 fraction maps. A significant fraction of short‐T2 signal was systematically observed in the skeletal muscle of all of the subjects .Conclusion: The proposed method allows the quantitative imaging of short‐T2 components in tissues containing fat. By also having the fat‐fraction and maps as outcomes, long‐T2 suppression is accomplished without requiring modifications to the basic UTE sequence. Although the hypersignal observed in the fasciae suggests that the short‐T2 signal observed in SKM might arise from interstitial connective tissue, further investigation is necessary to confirm this statement. Magn Reson Med 78:997–1008, 2017. © 2016 International Society for Magnetic Resonance in Medicine.Keywords
This publication has 29 references indexed in Scilit:
- T.P.6 Combination anti-inflammatory and anti-fibrotic treatment in muscular dystrophy – The more the better?Neuromuscular Disorders, 2012
- Fat-Corrected T2 Measurement as a Marker of Active Muscle Disease in Inflammatory MyopathyAmerican Journal of Roentgenology, 2012
- Short T2 contrast with three-dimensional ultrashort echo time imagingMagnetic Resonance Imaging, 2011
- Neuromuscular imaging in inherited muscle diseasesEuropean Radiology, 2010
- k‐space water‐fat decomposition with T2* estimation and multifrequency fat spectrum modeling for ultrashort echo time imagingJournal of Magnetic Resonance Imaging, 2010
- Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithmMagnetic Resonance in Medicine, 2009
- Multiecho water‐fat separation and simultaneous R estimation with multifrequency fat spectrum modelingMagnetic Resonance in Medicine, 2008
- Using adiabatic inversion pulses for long‐T2 suppression in ultrashort echo time (UTE) imagingMagnetic Resonance in Medicine, 2007
- Designing long‐T2 suppression pulses for ultrashort echo time imagingMagnetic Resonance in Medicine, 2006
- Variable-rate selective excitationJournal of Magnetic Resonance (1969), 1988