Implantation of a distractible titanium cage after cervical corpectomy: technical experience in 20 consecutive cases
Author:
- 31 August 2006
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 148 (11) , 1173-1180
Abstract
Background. This prospective observational study was undertaken to investigate the advantages, the safety, and the drawbacks of reconstructing a cervical corpectomy with a distractible corpectomy cage. According to the author’s literature search, this is the second clinical report on a distractible cervical corpectomy cage. Method. 20 consecutive patients underwent a single- or multi-level cervical corpectomy for spondylotic myelopathy, traumatic fracture, or tumor. The corpectomy defect was reconstructed by means of a distractible titanium cage, and local bone from the corpectomy was layed around the cage for fusion. An anterior cervical plate and/or a posterior lateral mass or pedicle screw fixation was added in all patients. The average follow-up was 14 months, and all patients had at least 12 months of follow-up. Findings. No hardware failure occurred in any of the patients. Construct stability was achieved in 19 out of 20 patients (95%) at 12 months postoperatively. The mean regional lordosis was 1° preoperatively, 9° postoperatively, and 7° at the follow-up. Mean neck pain on a VAS was 3.9 preoperatively, and 2.6 at 12 months. There were three perioperative complications: transient neurological worsening in one patient, one transient vocal cord paralysis, and persistent dysphagia in one patient. Conclusion. A single- or multi-level cervical corpectomy can be safely and effectively reconstructed by a distractible titanium cage and local bone graft in combination with anterior cervical plating and/or posterior lateral mass/pedicle screw fixation. Potential advantages of this technique are an unforced cage insertion in its non-distracted position, press-fitting the cage into the corpectomy defect through cage distraction, correction of kyphosis or preservation of local lordosis through cage distraction, and the absence of donor site morbidity. However, the stability rate in the current series did not exceed the fusion rates of auto- or allografts.Keywords
This publication has 19 references indexed in Scilit:
- A retrospective review of cervical corpectomy: indications, complications and outcomeActa Neurochirurgica, 2004
- Treatment of anterior communicating artery aneurysms: complementary aspects of microsurgical and endovascular proceduresJournal of Neurosurgery, 2003
- Graft Migration or Displacement After Multilevel Cervical Corpectomy and Strut GraftingSpine, 2003
- Early Reconstruction Failures After Multilevel Cervical CorpectomySpine, 2003
- Use of the Telescopic Plate Spacer in Treatment of Cervical and Cervicothoracic Spine TumorsNeurosurgery, 2002
- Anterior cervical corpectomy and strut graft fusion using a different methodThe Spine Journal, 2002
- Awake craniotomy with brain mapping as the routine surgical approach to treating patients with supratentorial intraaxial tumors: a prospective trial of 200 casesJournal of Neurosurgery, 1999
- Analysis of Harvest Morbidity and Radiographic Outcome Using Autograft for Anterior Cervical FusionSpine, 1997
- Multilevel anterior cervical corpectomy and fibular allograft fusion for cervical myelopathyJournal of Neurosurgery, 1997
- Fusion Rates in Multilevel Cervical Spondylosis Comparing Allograft Fibula with Autograft Fibula in 126 PatientsSpine, 1991