Scanning Electrochemical Microscopy in Combination with Piezoelectric Quartz Crystal Impedance Analysis for Studying the Growth and Electrochemistry as Well as Microetching of Poly(o-phenylenediamine) Thin Films
Authors:
- 12 February 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 109 (9) , 4053-4063
Abstract
The combination of scanning electrochemical microscopy (SECM) with piezoelectric quartz crystal impedance (PQCI) analysis was proposed as a novel multiparameter method for investigating the cyclic voltammetric growth of poly(o-phenylenediamine) (PoPD) thin films at Au electrodes in aqueous solutions of various pH values and the potentiostatic microetching (localized degradation) of these films in 0.10 mol/L aqueous H2SO4 for comparative examinations on polymer porosity and stability. Two potential-sweep ranges, −0.4 to 0.9 (I) and 0 to 0.9 (II) V versus SCE, and four solutions, acidic (A, 0.20 mol/L H2SO4 + 0.10 mol/L Na2SO4; B, 0.10 mol/L H2SO4 + 0.20 mol/L Na2SO4), neutral (C, 0.10 mol/L PBS + 0.20 mol/L Na2SO4, pH 7.2), and alkaline (D, 0.20 mol/L NaOH + 0.20 mol/L Na2SO4) aqueous solutions, were selected for PoPD growth. The pH increase for the polymerization solution increased the molar percentage of polyaniline-like chains in PoPD, as quantified from the current peaks at ∼0.6 V versus a saturated calomel electrode (SCE) for the oxidation of −NH2 groups in as-prepared PoPD (grown from solutions C and D) during their redox switching in 0.10 mol/L aqueous H2SO4 for the first time. The unusual PQCI responses observed at negative potentials (potential range I) in the first several potential cycles during the cyclic voltammetric growth of PoPD in acidic and neutral solutions have been reasonably explained as being due to the precipitation/dissolution of the poorly soluble phenazinehydrine charge-transfer complexes developed during redox switching of oligomers for the first time, which brought about much less compact PoPD films and their higher degradability than those grown in the same solution but over potential range II. SECM, scanning electron microscopy (SEM), and piezoelectric quartz crystal (PQC) frequency were used to estimate the sizes of etched microscale spots. In addition, the x-, y-, or z-axis movement of a Pt microelectrode of 25-μm diameter near the PQC electrode was found to influence negligibly the PQCI responses in 1.0 mol/L aqueous Na2SO4 containing K4Fe(CN)6 up to 0.10 mol/L, and a new protocol of dynamically electrodepositing silver microwires via the chemical-lens method was proposed for examining the local mass-sensitivity distribution on the PQC surface.Keywords
This publication has 53 references indexed in Scilit:
- Adsorption and precipitation during the redox transformations of phenazineElectrochimica Acta, 2004
- Electroanalytical measurements using the scanning electrochemical microscopeAnalytica Chimica Acta, 2000
- Viscoelastic Changes in Os-Containing Poly(allylamine) Based Redox Hydrogels for Amperometric Enzyme Electrodes: An EQCM StudyThe Journal of Physical Chemistry B, 1999
- High resolution studies of heterogeneous processes with the scanning electrochemical microscopeMicrochimica Acta, 1999
- Scanning Electrode Quartz Crystal Analysis. Back-Scanning Mode and Application to Electrochemical MeasurementsAnalytical Sciences, 1999
- Electrochemistry of tert-Butylcalix[8]arene−C60 Films Using a Scanning Electrochemical Microscope−Quartz Crystal MicrobalanceAnalytical Chemistry, 1998
- Scanning Electrode Quartz Crystal AnalysisAnalytical Chemistry, 1997
- Hole injection and etching studies of gallium arsenide using the scanning electrochemical microscopeLangmuir, 1990
- Scanning Electrochemical Microscopy: The Application of the Feedback Mode for High Resolution Copper EtchingJournal of the Electrochemical Society, 1989
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959