A comparison of global indices between the Medmont Automated Perimeter and the Humphrey Field Analyzer
- 27 March 2007
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 91 (10) , 1285-1287
Abstract
Background: Two commonly used perimeters in Australia are the Humphrey Field Analyzer II (HFA) and the Medmont Automated Perimeter (MAP). Each device describes the visual field in terms of numerical values called global indices; however, these values are not interchangeable between devices. This study was designed to directly compare the global indices of HFA and MAP visual fields. Methods: 63 subjects who had suspected glaucoma, ocular hypertension or glaucoma, or were normal controls were recruited selectively. Each patient was tested with the MAP and HFA. Global indices were then compared between tests. These included mean deviation (MD) and pattern standard deviation (PSD) from the HFA and average defect (AD) and pattern defect (PD) from the MAP. Results: The MD and PSD results were strongly correlated with the AD and PD results, respectively. The relationship between them could be described in terms of two polynomial equations: AD = 0.94+1.31(MD)+0.02(MD)2 and PD = 2.21(PSD)–0.05(PSD)2–0.006. These non-linear relationships may be the result of differences in testing method (test stimulus spectrum, number of testing locations or background luminance) or differences in the way each global index was calculated. Conclusion: The AD and PD results obtained from the MAP may be substituted for the MD and PSD results from the HFA after appropriate conversion.Keywords
This publication has 14 references indexed in Scilit:
- Robust Indices of Clinical Data: Meaningless MeansInvestigative Ophthalmology & Visual Science, 2005
- Validation of a Predictive Model to Estimate the Risk of Conversion From Ocular Hypertension to GlaucomaArchives of Ophthalmology (1950), 2005
- Visual field changes after cataract extraction: The AGIS experienceAmerican Journal of Ophthalmology, 2004
- A comparison of perimetric results with the Medmont and Humphrey perimetersBritish Journal of Ophthalmology, 2003
- The Ocular Hypertension Treatment StudyArchives of Ophthalmology (1950), 2002
- The effects of weighting the ?mean defect? visual field index according to threshold variability in the central and midperipheral visual fieldGraefe's Archive for Clinical and Experimental Ophthalmology, 1991
- The Opticom M‐600™: A new LED automated perimeterClinical and Experimental Optometry, 1990
- Automated Suprathreshold Static PerimetryAmerican Journal of Ophthalmology, 1980
- Clinical Experiences with the Use of an Automated Perimeter (Otopus) in the Diagnosis and Management of Patients With Glaucoma and Neurologic DiseasesOphthalmology, 1979
- Automatic perimetry in glaucoma visual field screeningGraefe's Archive for Clinical and Experimental Ophthalmology, 1976