Motion-compensated noninvasive periodontal health monitoring using handheld and motor-based photoacoustic-ultrasound imaging systems
- 23 February 2021
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (3) , 1543-1558
Abstract
Simultaneous visualization of the teeth and periodontium is of significant clinical interest for image-based monitoring of periodontal health. We recently reported the application of a dual-modality photoacoustic-ultrasound (PA-US) imaging system for resolving periodontal anatomy and periodontal pocket depths in humans. This work utilized a linear array transducer attached to a stepper motor to generate 3D images via maximum intensity projection. This prior work also used a medical head immobilizer to reduce artifacts during volume rendering caused by motion from the subject (e.g., breathing, minor head movements). However, this solution does not completely eliminate motion artifacts while also complicating the imaging procedure and causing patient discomfort. To address this issue, we report the implementation of an image registration technique to correctly align B-mode PA-US images and generate artifact-free 2D cross-sections. Application of the deshaking technique to PA phantoms revealed 80% similarity to the ground truth when shaking was intentionally applied during stepper motor scans. Images from handheld sweeps could also be deshaken using an LED PA-US scanner. In ex vivo porcine mandibles, pigmentation of the enamel was well-estimated within 0.1 mm error. The pocket depth measured in a healthy human subject was also in good agreement with our prior study. This report demonstrates that a modality-independent registration technique can be applied to clinically relevant PA-US scans of the periodontium to reduce operator burden of skill and subject discomfort while showing potential for handheld clinical periodontal imaging.Keywords
Funding Information
- National Science Foundation (DGE-1650112)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (116310008)
- National Institutes of Health (1R21AG065776, DP2 137187, R21 DE029025, R21 DE029917, S10 OD021821)
This publication has 29 references indexed in Scilit:
- The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical ImagingIEEE Transactions on Medical Imaging, 2014
- Deformable Medical Image Registration: A SurveyIEEE Transactions on Medical Imaging, 2013
- Periodontitis and atherosclerotic cardiovascular disease: consensus report of the Joint EFP/AAPWorkshop on Periodontitis and Systemic DiseasesJournal of Periodontology, 2013
- MIND: Modality independent neighbourhood descriptor for multi-modal deformable registrationMedical Image Analysis, 2012
- Prevalence of Periodontitis in Adults in the United States: 2009 and 2010Journal of Dental Research, 2012
- Medical image registration based on SURF detectorPattern Recognition and Image Analysis, 2011
- Mapping the Pathogenesis of Periodontitis: A New LookJournal of Periodontology, 2008
- Freehand 3D Ultrasound Reconstruction Algorithms—A ReviewUltrasound in Medicine & Biology, 2007
- Distinctive Image Features from Scale-Invariant KeypointsInternational Journal of Computer Vision, 2004
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004