Intrinsic respiratory gating in small-animal CT
- 23 April 2008
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 18 (7) , 1375-1384
Abstract
Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging.Keywords
This publication has 21 references indexed in Scilit:
- Retrospective Motion Gating in Small Animal CT of Mice and RatsInvestigative Radiology, 2007
- Fast Retrospectively Gated Quantitative Four-Dimensional (4D) Cardiac Micro Computed Tomography Imaging of Free-Breathing MiceInvestigative Radiology, 2007
- Free-Breathing Three-Dimensional Computed Tomography of the Lung Using Prospective Respiratory GatingInvestigative Radiology, 2006
- Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodentsMagnetic Resonance in Medicine, 2005
- Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography1Academic Radiology, 2004
- Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesisNature Medicine, 2004
- Improved method ofin vivorespiratory-gated micro-CT imagingPhysics in Medicine & Biology, 2004
- Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: a simulation studyIEEE Transactions on Information Technology in Biomedicine, 2003
- Kymogram detection and kymogram‐correlated image reconstruction from subsecond spiral computed tomography scans of the heartMedical Physics, 2002
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984