Screening for Obstructive Sleep Apnea by Cyclic Variation of Heart Rate
Authors:
- Junichiro HayanoJHJunichiro Hayano
- Eiichi WatanabeEWEiichi Watanabe
- Yuji SaitoYSYuji Saito
- Fumihiko SasakiFSFumihiko Sasaki
- Keisaku FujimotoKFKeisaku Fujimoto
- Tetsuo NomiyamaTetsuo Nomiyama
- Kiyohiro KawaiKKKiyohiro Kawai
- Itsuo KodamaIKItsuo Kodama
- Hiroki SakakibaraHSHiroki Sakakibara
- 1 February 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 4 (1) , 64-72
Abstract
Background—: Despite the adverse cardiovascular consequences of obstructive sleep apnea, the majority of patients remain undiagnosed. To explore an efficient ECG-based screening tool for obstructive sleep apnea, we examined the usefulness of automated detection of cyclic variation of heart rate (CVHR) in a large-scale controlled clinical setting. Methods and Results—: We developed an algorithm of autocorrelated wave detection with adaptive threshold (ACAT). The algorithm was optimized with 63 sleep studies in a training cohort, and its performance was confirmed with 70 sleep studies of the Physionet Apnea-ECG database. We then applied the algorithm to ECGs extracted from all-night polysomnograms in 862 consecutive subjects referred for diagnostic sleep study. The number of CVHR per hour (the CVHR index) closely correlated ( r =0.84) with the apnea-hypopnea index, although the absolute agreement with the apnea-hypopnea index was modest (the upper and lower limits of agreement, 21 per hour and −19 per hour) with periodic leg movement causing most of the disagreement ( P <0.001). The CVHR index showed a good performance in identifying the patients with an apnea-hypopnea index ≥15 per hour (area under the receiver-operating characteristic curve, 0.913; 83% sensitivity and 88% specificity, with the predetermined cutoff threshold of CVHR index ≥15 per hour). The classification performance was unaffected by older age (≥65 years) or cardiac autonomic dysfunction (SD of normal-to-normal R-R intervals over the entire length of recording <65 ms; area under the receiver-operating characteristic curve, 0.915 and 0.911, respectively). Conclusions—: The automated detection of CVHR with the ACAT algorithm provides a powerful ECG-based screening tool for moderate-to-severe obstructive sleep apnea, even in older subjects and in those with cardiac autonomic dysfunction.Keywords
This publication has 28 references indexed in Scilit:
- Triggering of Nocturnal Arrhythmias by Sleep-Disordered Breathing EventsJACC, 2009
- Faculty Opinions recommendation of Sleep disordered breathing and mortality: eighteen-year follow-up of the Wisconsin sleep cohort.2008
- Treatment of Obstructive Sleep Apnea Is Associated With Decreased Cardiac Death After Percutaneous Coronary InterventionJACC, 2007
- Association of Nocturnal Arrhythmias with Sleep-disordered BreathingAmerican Journal of Respiratory and Critical Care Medicine, 2006
- Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational studyThe Lancet, 2005
- Sleep-Related Breathing Disorders Are Associated With Ventricular Arrhythmias in Patients With an Implantable Cardioverter-DefibrillatorChest, 2002
- Sympathetic neural mechanisms in obstructive sleep apnea.Journal of Clinical Investigation, 1995
- Surges of muscle sympathetic nerve activity during obstructive apnea are linked to hypoxemiaJournal of Applied Physiology, 1995
- Relationship of Ventricular Ectopy to Oxyhemoglobin Desaturation in Patients with Obstructive Sleep ApneaChest, 1985
- Cardiac arrhythmia and conduction disturbances during sleep in 400 patients with sleep apnea syndromeThe American Journal of Cardiology, 1983