Waveguide micro-opto-electro-mechanical resonant chemical sensors
- 1 January 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (6) , 762-768
Abstract
We demonstrate a silicon micro-opto-electro-mechanical sensor based on mass-loading of a chemo-selective polymer coated onto a microbridge. The sensor is probed optically using an on-chip waveguide Fabry–Pérot interferometer for high resolution displacement and resonant frequency measurement. The mechanical resonator is designed with paddles to simplify chemo-selective polymer deposition and to minimize any strain effects from the polymer during analyte sorption. Water vapor sensing experiments indicate mass-loading with minimum humidity detection of ΔRH = 0.25% corresponding to a measured limit-of-detection of 68 parts-per-million. The sensor response time constant is 30 s with minimum frequency noise of 58 Hz at 149.4 kHz resonance. The measured mass-loading resolution is 4.6 picograms. We extract the chemo-selective polymer's partition coefficient and confirm that strong sorption and mass-loading occurs. Various device improvements are discussed, including scaling up to large single-chip sensor arrays, increasing mass-loading resolution by adjusting the device geometry, and using other chemo-selective polymers with larger partition coefficients. These improvements suggest parts-per-billion limit-of-detection levels for a variety of toxic chemicals.Keywords
This publication has 15 references indexed in Scilit:
- A multiplexed optofluidic biomolecular sensor for low mass detectionLab on a Chip, 2009
- In-plane microelectromechanical resonator with integrated Fabry–Pérot cavityApplied Physics Letters, 2008
- Chemical vapor discrimination using a compact and low-power array of piezoresistive microcantileversThe Analyst, 2008
- Micro- and nanomechanical sensors for environmental, chemical, and biological detectionLab on a Chip, 2007
- Microfluidic flow rate detection based on integrated optical fiber cantileverLab on a Chip, 2007
- Measured limits of detection based on thermal-mechanical frequency noise in micromechanical sensorsApplied Physics Letters, 2007
- Radiation-pressure cooling and optomechanical instability of a micromirrorNature, 2006
- End-coupled optical waveguide MEMS devices in the indium phosphide material systemJournal of Micromechanics and Microengineering, 2006
- Attogram detection using nanoelectromechanical oscillatorsJournal of Applied Physics, 2004
- Detection of mercury vapor using resonating microcantileversApplied Physics Letters, 1995