A kernel-based method for markerless tumor tracking in kV fluoroscopic images
Authors:
- Noriyasu HommaNHNoriyasu Homma
- Kei IchijiKIKei Ichiji
- Makoto AbeMAMakoto Abe
- Norihiro SugitaNSNorihiro Sugita
- Yoshihiro TakaiYTYoshihiro Takai
- Yuichiro NaritaYNYuichiro Narita
- Makoto YoshizawaMYMakoto Yoshizawa
- 7 August 2014
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (17) , 4897-4911
Abstract
Markerless tracking of respiration-induced tumor motion in kilo-voltage (kV) fluoroscopic image sequence is still a challenging task in real time image-guided radiation therapy (IGRT). Most of existing markerless tracking methods are based on a template matching technique or its extensions that are frequently sensitive to non-rigid tumor deformation and involve expensive computation. This paper presents a kernel-based method that is capable of tracking tumor motion in kV fluoroscopic image sequence with robust performance and low computational cost. The proposed tracking system consists of the following three steps. To enhance the contrast of kV fluoroscopic image, we firstly utilize a histogram equalization to transform the intensities of original images to a wider dynamical intensity range. A tumor target in the first frame is then represented by using a histogram-based feature vector. Subsequently, the target tracking is then formulated by maximizing a Bhattacharyya coefficient that measures the similarity between the tumor target and its candidates in the subsequent frames. The numerical solution for maximizing the Bhattacharyya coefficient is performed by a mean-shift algorithm. The proposed method was evaluated by using four clinical kV fluoroscopic image sequences. For comparison, we also implement four conventional template matching-based methods and compare their performance with our proposed method in terms of the tracking accuracy and computational cost. Experimental results demonstrated that the proposed method is superior to conventional template matching-based methods.Keywords
This publication has 32 references indexed in Scilit:
- Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markersPhysics in Medicine & Biology, 2007
- Robust fluoroscopic respiratory gating for lung cancer radiotherapy without implanted fiducial markersPhysics in Medicine & Biology, 2007
- Residual motion of lung tumors in end‐of‐inhale respiratory gated radiotherapy based on external surrogatesMedical Physics, 2006
- Relation of external surface to internal tumor motion studied with cine CTMedical Physics, 2006
- Towards fluoroscopic respiratory gating for lung tumours without radiopaque markersPhysics in Medicine & Biology, 2005
- A phantom evaluation of a stereo‐vision surface imaging system for radiotherapy patient setupMedical Physics, 2005
- CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax RateRadiology, 2003
- Kernel-based object trackingIEEE Transactions on Pattern Analysis and Machine Intelligence, 2003
- Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopyCancer, 2002
- Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001