Study on axial compression bearing capacity of in-sulated sandwich concrete wall with embedded columns
Authors:
- 13 November 2022
- journal article
- research article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (4) , 785-805
Abstract
An insulated sandwich concrete wall with embedded columns (ISCW-EC) is proposed by introducing horizontal reinforcements and cold formed steel embedded columns to the traditional insulated sandwich concrete wall. Axial compression load tests were performed on two full-scale specimens with different horizontal reinforcement spacings to investigate the failure mode of ISCW-EC. The failure patterns of both specimens are the same: splitting cracks present at the bottom of specimen and local buckling occurs at the bottom of the embedded column. The test results show that the specimen with smaller horizontal reinforcement spacing has smaller cracking load, lower secant stiffness, lower ductility and higher compression bearing capacity. Based on the test results, refined finite element models were established to perform a multi-parameter analysis in which the influences of horizontal reinforcement spacing, embedded column spacing, concrete strength and steel wire diameter are studied. The multi-parameter analysis results show that the increase of concrete strength and wire diameter improve the axial compression bearing capacity while the increase of the horizontal reinforcement spacing and embedded column spacing reduce it. Finally, the calculation formula of axial compression capacity of ISCW-EC is put forward based on both test and finite element analysis results.Keywords
Funding Information
- Top Youth Talent Funding of Hebei Province
- Natural Science Foundation of Hebei Province (E2020210074)
- Natural Science Foundation of Hebei Province (E2022210084)
- Local Science and Technology Development Fund Project Guided by Central Government (206Z7601G)
This publication has 20 references indexed in Scilit:
- Thermal performance of precast concrete sandwich walls with a novel hybrid connectorEnergy and Buildings, 2018
- Thermal Evaluation of Common Locations of Heat Loss in Sandwich Wall Panels2017
- Analysis and Parametric Study of Partially Composite Precast Concrete Sandwich Panels under Axial LoadsJournal of Structural Engineering, 2016
- Bending behaviour of Textile Reinforced Concrete sandwich beamsConstruction and Building Materials, 2015
- Composite Behavior of a Novel Insulated Concrete Sandwich Wall Panel Reinforced with GFRP Shear Grids: Effects of Insulation TypesMaterials, 2015
- Thermal response of precast concrete sandwich walls with various steel connectors for architectural buildings in cold regionsEnergy and Buildings, 2014
- Experimental tests and numerical modelling of wall sandwich panelsEngineering Structures, 2012
- Testing of Precast Lightweight Foamed Concrete Sandwich Panel with Single and Double Symmetrical Shear Truss Connectors under Eccentric LoadingAdvanced Materials Research, 2011
- Response of pre-cast reinforced composite sandwich panels to axial loadingConstruction and Building Materials, 2007
- Thermal performance evaluation of precast concrete three-wythe sandwich wall panelsEnergy and Buildings, 2006