Angular Irradiation Methods for DOI Calibration of Light-Sharing Detectors—A Perspective for PET In-System Calibration
Open Access
- 15 May 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 673-683
Abstract
Typical positron emission tomography (PET) detectors consist of one-layer segmented scintillators coupled to silicon photomultipliers (SiPMs). Light-sharing detectors, e.g., semi-monoliths, additionally provide depth-of-interaction (DOI) estimation, performing best when calibrated individually. To establish those designs in large PET systems, scalable (re-)calibration methods are needed, possibly transferable to assembled systems. Here, two DOI calibration methods, potentially allowing in-system calibration, are evaluated and compared with an established calibration scheme. Both methods are based on angular detector irradiation using a fan-beam slit collimator and gradient tree boosting (GTB) for 3-Dimensional (3D) position estimation. The positioning performance was assessed for irradiation angles between 0∘ (lateral) and 90∘ (detector normal). With lateral irradiation, a unique DOI position is given, whereas with angular irradiation a gamma-individual reference position must be retrieved. The first method employs one angular beam and calculates DOI from the beam path and planar position estimation. The second method uses two intersecting beams. The intersection defines DOI for gamma interactions that are spatially localized there. Those gamma photons are identified by light distribution comparison using a nearest-neighbor routine. The methods were evaluated on a semimonolithic LYSO slab detector (32×3.9×19 mm slabs). Both methods performed similarly to the benchmark lateral irradiation within 1 %, and 6 %, respectively, for shallow irradiation angles up to 45∘.Keywords
Funding Information
- Federal Ministry of Education and Research (13GW0621B)
This publication has 52 references indexed in Scilit:
- Probabilities of triggering and validation in a digital silicon photomultiplierJournal of Instrumentation, 2014
- 3D position estimation using an artificial neural network for a continuous scintillator PET detectorPhysics in Medicine & Biology, 2013
- Refractive Index of Silicon atRay EnergiesPhysical Review Letters, 2012
- Monolithic LaBr3:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomographyPhysics in Medicine & Biology, 2012
- A practical method for depth of interaction determination in monolithic scintillator PET detectorsPhysics in Medicine & Biology, 2011
- Nonlinear least-squares modeling of 3D interaction position in a monolithic scintillator blockPhysics in Medicine & Biology, 2010
- Clinical Applications of PET and PET-CTMedical Journal Armed Forces India, 2009
- Parametric positioning of a continuous crystal PET detector with depth of interaction decodingPhysics in Medicine & Biology, 2008
- From PET detectors to PET scannersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- The Beer-Lambert LawJournal of Chemical Education, 1962