Improved DR typing of cadaver donor by lymphocyte incubation

Authors:

Abstract
Of 39 consecutive cadaver donors tested, DR antigens could not be detected in 17. Following 3 h incubation of the B lymphocytes at 37°C, eight of the donors with no detectable DR antigens had two DR antigens and nine had one DR antigen. In addition, there were nine cases in which a potential cadaver donor had one antigen before incubation and two DR antigens following incubation. The simple technique of pre‐incubating B lymphocytes before testing has helped considerably in prospec‐ tively typing cadaver donors for HLA‐DR.