Evaluation of chest compression effect on airway management with air-Q®, aura-i®, i-gel®, and Fastrack® intubating supraglottic devices by novice physicians: a randomized crossover simulation study
- 22 February 2014
- journal article
- research article
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (5) , 676-680
Abstract
In the 2010 American Heart Association guidelines, supraglottic devices (SGDs) such as the laryngeal mask are proposed as alternatives to tracheal intubation for cardiopulmonary resuscitation. Some SGDs can also serve as a means for tracheal intubation after successful ventilation. The purpose of this study was to evaluate the effect of chest compression on airway management with four intubating SGDs, aura-i® (aura-i), air-Q® (air-Q), i-gel® (i-gel), and Fastrack® (Fastrack), during cardiopulmonary resuscitation using a manikin. Twenty novice physicians inserted the four intubating SGDs into a manikin with or without chest compression. Insertion time and successful ventilation rate were measured. For cases of successful ventilation, blind tracheal intubation via the intubating SGD was performed with chest compression and success or failure within 30 s was recorded. Chest compression did not decrease the ventilation success rate of the four intubating SGDs (without chest compression (success/total): air-Q, 19/20; aura-i, 19/20; i-gel, 18/20; Fastrack, 19/20; with chest compression: air-Q, 19/20; aura-i, 19/20; i-gel, 16/20; Fastrack, 18/20). Insertion time was significantly lengthened by chest compression in the i-gel trial (P < 0.05), but not with the other three devices. The blind intubation success rate with chest compression was the highest in the air-Q trial (air-Q, 15/19; aura-i, 14/19; i-gel, 12/16; Fastrack, 10/18). This simulation study revealed the utility of intubating SGDs for airway management during chest compression.Keywords
This publication has 23 references indexed in Scilit:
- Performance of the i-gel™ during pre-hospital cardiopulmonary resuscitationResuscitation, 2013
- Practice Guidelines for Management of the Difficult AirwayAnesthesiology, 2013
- Comparison of Supreme® and Soft Seal® laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin studyJournal of Anesthesia, 2010
- Part 8: Adult Advanced Cardiovascular Life SupportCirculation, 2010
- Part 1: Executive SummaryCirculation, 2010
- Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the groundJournal of Anesthesia, 2010
- Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin studyJournal of Anesthesia, 2010
- Interruptions in Cardiopulmonary Resuscitation From Paramedic Endotracheal IntubationAnnals of Emergency Medicine, 2009
- Intubating laryngeal mask for fibreoptic intubation — particularly useful during neck stabilizationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2000
- Comparison of Placement of the Laryngeal Mask Airway With Endotracheal Tube by Paramedics and Respiratory TherapistsAnnals of Emergency Medicine, 1994