Comparison of Lesion Detection in the Transverse and Coronal Views on Automated Breast Sonography
Open Access
- 1 January 2015
- journal article
- research article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 34 (1) , 125-135
Abstract
Objectives The purpose of our study was to compare the accuracy of detection of lesions in the coronal and transverse views on automated breast sonography. Methods Three breast radiologists independently interpreted automated breast sonograms from 113 women: 14 with negative findings and 99 with known breast lesions (99 benign and 53 malignant findings). The readers were asked to detect the presence or absence of the abnormalities using the transverse and coronal views in different reading sessions. If a lesion was detected, we evaluated its location, sonographic features, including shape, orientation, margin, boundary type, and echo pattern, and final American College of Radiology Breast Imaging Reporting and Data System assessment category. The reading time was also evaluated. Results Of 456 potential detections (152 lesions with 3 readers), 80.5% of the detections were made with the transverse view, and 67.3% were made with the coronal view. The detection rates for both malignant and benign lesions were significantly higher for the transverse view than for the coronal view (P < .001). The reading time for the coronal view was less than that for the transverse view (mean ± SD, 3.83 ± 1.71 versus 5.57 ± 2.21 minutes). The intraclass correlation coefficient values for lesion location, distance from the nipple, and lesion size for both views all exceeded 0.7. Conclusions Although the coronal view on automated breast sonography showed comparable reliability and a shorter reading time, the detection rate for the coronal view was significantly lower than that for the transverse view in both benign and malignant lesions. It is preferable to reserve the coronal view as an additional method to the transverse view.Keywords
This publication has 20 references indexed in Scilit:
- The Clinical Utility of Automated Breast Volume Scanner: A Pilot Study of 139 CasesJournal of Breast Cancer, 2013
- Automated 3-D Breast Ultrasound as a Promising Adjunctive Screening Tool for Examining Dense Breast TissueSeminars in Roentgenology, 2011
- Automated Ultrasound of the Breast for Diagnosis: Interobserver Agreement on Lesion Detection and CharacterizationAmerican Journal of Roentgenology, 2011
- Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound dataActa Radiologica, 2011
- Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breastsEuropean Radiology, 2009
- Combined Screening With Ultrasound and Mammography vs Mammography Alone in Women at Elevated Risk of Breast CancerJAMA, 2008
- Observer variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasoundEuropean Journal of Radiology, 2008
- The randomized trials of breast cancer screening: what have we learned?Radiologic Clinics of North America, 2004
- Incidental findings on sonography of the breast: clinical significance and diagnostic workup.American Journal of Roentgenology, 1999
- Analysis of normal breast tissue and of solid breast masses using three‐dimensional ultrasound mammographyUltrasound in Obstetrics & Gynecology, 1999