General SVPWM strategy for three different four‐switch three‐phase inverters
Authors:
Open Access
- 1 February 2015
- journal article
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 51 (4) , 357-359
Abstract
Four-switch three-phase inverters (FSTPIs) are post-fault reconfigured topologies for a two-level inverter with failure of a power switch or a leg, and space vector pulse-width modulation (SVPWM) strategies have been used to control FSTPIs. However, different faulty legs correspond to different topologies of FSTPIs which are controlled by different SVPWM strategies; therefore, three SVPWM strategies need to be prepared for three FSTPIs, respectively, which takes up lots of memory space in the controller and increases the complexity of the control strategy. To overcome these disadvantages, a general SVPWM strategy that can be used to control three FSTPIs is proposed. Experimental results have shown the validity and feasibility of the proposed strategy.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (2682013ZT19)
This publication has 5 references indexed in Scilit:
- A Comprehensive Investigation of Four-Switch Three-Phase Voltage Source Inverter Based on Double Fourier Integral AnalysisIEEE Transactions on Power Electronics, 2011
- Scalar PWM algorithms for four-switch three-phase invertersElectronics Letters, 2010
- A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power InvertersIEEE Transactions on Industry Applications, 2009
- A General PWM Strategy for Four-Switch Three-Phase InvertersIEEE Transactions on Power Electronics, 2006
- Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive SystemsIEEE Transactions on Industrial Electronics, 2004