Electron-Excited Energy Dispersive X-Ray Spectrometry at High Speed and at High Resolution: Silicon Drift Detectors and Microcalorimeters
- 1 July 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 12 (6) , 527-537
Abstract
Two recent developments in X-ray spectrometer technology provide dramatic improvements in analytical capabilities that impact the frontiers of electron microscopy. Silicon drift detectors (SDD) use the same physics as silicon (lithium) energy dispersive spectrometers [Si(Li) EDS] but differ in design: only 10% of the thickness of the Si(Li) EDS with an anode area below 0.1 mm2and a complex rear surface electrode pattern that creates a lateral internal charge collection field. The SDD equals or betters the Si(Li) EDS in most measures of performance. For output versus input count rate, the SDD exceeds the Si(Li) EDS by a factor of 5 to 10 for the same resolution. This high throughput can benefit analytical measurements that are count limited, such as X-ray mapping and trace measurements. The microcalorimeter EDS determines the X-ray energy by measuring the temperature rise in a metal absorber. Operating at 100 mK, the microcalorimeter EDS achieves resolution of 2–5 eV over a photon energy range of 200 eV to 10 keV in energy dispersive operation, eliminating most peak interference situations and providing high peak-to-background to detect low fluorescence yield peaks. Chemical bonding effects on low energy (<2 keV) peak shapes can be measured.Keywords
This publication has 22 references indexed in Scilit:
- XEDS Systems for the Next Generation Analytical Electron MicroscopeMicroscopy and Microanalysis, 2004
- Observation of Nanometer-Xe Clusters Embedded in Al CrystalsMicroscopy and Microanalysis, 2004
- Performance of 32-channel time-division SQUID multiplexer for cryogenic detector arraysIEEE Transactions on Applied Superconductivity, 2003
- Electronics for arrays of transition edge sensors using digital signal processingIEEE Transactions on Applied Superconductivity, 2003
- Microcalorimeter energy‐dispersive spectrometry using a low voltage scanning electron microscopeJournal of Microscopy, 2000
- Lowering the limit of detection in high spatial resolution electron beam microanalysis with the microcalorimeter energy dispersive X-ray spectrometerUltramicroscopy, 1999
- High‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysisJournal of Microscopy, 1997
- X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedbackApplied Physics Letters, 1996
- A self-biasing cryogenic particle detector utilizing electrothermal feedback and a SQUID readoutIEEE Transactions on Applied Superconductivity, 1995
- Solid-State Energy-Dispersion Spectrometer for Electron-Microprobe X-ray AnalysisScience, 1968