Ultrasonic‐based protein quantitation by 18 O‐labeling: optimization and comparison between different procedures
- 13 December 2010
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (1) , 75-87
Abstract
Herein we report results regarding the optimization and comparison between different ultrasonic‐based procedures for protein quantitation by the direct 18 O‐labeling approach. The labeling procedure was evaluated using different proteins, different ultrasonic devices and different reaction times: from 30 s to 10 min with the ultrasonic probe and from 30 s to 30 min with the sonoreactor. Variables such as the enzyme‐to‐protein ratio and protein concentration were also assessed. The results show that it is possible to accelerate the labeling reaction from 12 h to only 15 min with the sonoreactor without compromising the labeling efficiency. A larger variation in the double labeling yield was obtained among the different peptides, but the values for the smaller peptides are similar to the ones achieved with the classic methodology. These findings were further confirmed by labeling a complex protein mixture from human plasma. It was also found that the labeling reaction is affected by the sample concentration, even when performed with the classic overnight procedure. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 36 references indexed in Scilit:
- Can ultrasonic energy efficiently speed 18O‐labeling of proteins?Proteomics, 2009
- 18O Stable Isotope Labeling in MS-based ProteomicsBriefings in Functional Genomics and Proteomics, 2009
- Rapid Sample Processing for LC-MS-Based Quantitative Proteomics Using High Intensity Focused UltrasoundJournal of Proteome Research, 2008
- Minimizing Back Exchange in 18O/16O Quantitative Proteomics Experiments by Incorporation of Immobilized Trypsin into the Initial Digestion StepAnalytical Chemistry, 2007
- Sonoreactor-Based Technology for Fast High-Throughput Proteolytic Digestion of ProteinsJournal of Proteome Research, 2006
- Trypsin is the primary mechanism by which the 18O isotopic label is lost in quantitative proteomic studiesAnalytical Biochemistry, 2006
- Regression analysis for comparing protein samples with 16O/18O stable-isotope labeled mass spectrometryBioinformatics, 2006
- Quantitative proteome analysis of breast cancer cell lines using 18 O‐labeling and an accurate mass and time tag strategyProteomics, 2006
- Effects of Calcium Binding on Structure and Autolysis Regulation in Trypsins. A Molecular Dynamics InvestigationJournal of Chemical Theory and Computation, 2005
- Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging ReagentsMolecular & Cellular Proteomics, 2004