True rotational stability of a single-piece hydrophobic intraocular lens
Authors:
- 17 April 2018
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 103 (2) , 186-190
Abstract
Background To evaluate rotation and its influencing factors of an aspheric one-piece hydrophobic acrylic intraocular lens (IOL) Vivinex XY1 during 6 months after operation. Methods In this institutional trial, 122 eyes of 66 patients were implanted with a non-toric aspheric IOL Vivinex XY1 (Hoya Corporation, Tokyo, Japan). IOL alignment was assessed at the end of surgery, 1 hour, 1 week, 1 month and 6 months after implantation. Confounding factors such as axial length, presence of anterior fibrosis and randomised implantation in four different intended axes (0°, 45°, 90°, 135°) were evaluated. Decentration and tilt were measured using a Purkinje metre. Results Assessment of rotational stability was possible for 103 of 122 implanted IOLs 6 months after eye surgery. The median absolute rotation was 1.1° (range: 0°–5°). Rotation was significantly increased within the first hour after operation compared with later time-points (pConclusion Assessing the true IOL position at the end of surgery is crucial for the evaluation of rotational stability of IOLs. No IOL rotation exceeding 5° could be detected 6 months after surgery.Keywords
This publication has 25 references indexed in Scilit:
- Rotational Stability and Patient Satisfaction after Implantation of a New Toric IOLEuropean Journal of Ophthalmology, 2015
- Toric vs Aspherical Control Intraocular Lenses in Patients With Cataract and Corneal AstigmatismJAMA Ophthalmology, 2014
- Rotational Stability of a Single-Piece Toric Acrylic Intraocular Lens: A Pilot StudyAmerican Journal of Ophthalmology, 2014
- Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bagJournal of Cataract & Refractive Surgery, 2012
- Rotational stability of a single-piece toric acrylic intraocular lensJournal of Cataract & Refractive Surgery, 2010
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lensesBritish Journal of Ophthalmology, 2010
- Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort studyBMC Ophthalmology, 2008
- Evaluating the eye's rotational stability during standard photographyJournal of Cataract & Refractive Surgery, 2005
- Toric intraocular lenses: Correcting astigmatism while controlling axis shiftJournal of Cataract & Refractive Surgery, 1994