Noise and thermal performance of a sub-attofarad capacitance sensor for precision measurements, with applications in gravitational wave detectors
Open Access
- 1 March 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Abstract
We describe the design principles, fabrication, and characterization of a precision AC resonant capacitance bridge (RCB) sensor, based on a resonant differential planar printed circuit board transformer with a solid (ungapped) MnZn ferrite core, demonstrating a short-term sensitivity at 293 K of 0.225 ± 0.005 aF/√Hz at around 120 kHz resonance frequency and 1 Hz Fourier measurement frequency. At 120 K, the RCB short term noise sensitivity is 0.118 ± 0.005 aF/√Hz. We compare the ungapped configuration to five different RCBs: three with a core gap of 65 μm and two with a core gap of 130 μm. Their average room temperature short term noise sensitivities are 0.30 ± 0.01 and 0.45 ± 0.01 aF/√Hz, while the cryogenic operation of these transformers at 120 K resulted in averaged sensitivities of 0.23 ± 0.01 and 0.36 ± 0.01 aF/√Hz, respectively. Multi-hour room temperature runs, with one core of each of the three gap types, proved the stability of their long-term sensitivities of 0.234 ± 0.005, 0.338 ± 0.009, and 0.435 ± 0.010 aF/√Hz for the ungapped (40-h duration) and the 65 and 130 μm (28-h duration) cores, respectively. At 0.1 mHz, a critical frequency for space gravitational wave detectors, the respective sensitivities are 0.25 ± 0.02, 0.35 ± 0.02, and 0.53 ± 0.07 aF/√Hz. Measurements with the ungapped transformer configuration for temperatures from 325 to 349 K further validate the dependence of the noise model on temperature and permeability. The performance of our RCB with an ungapped core matches the calculated performance value and shows an improvement in signal-to-noise ratio of two or more compared with capacitance bridges developed for similar applications. A further factor of about two noise reductions is achieved by cooling to 120 K.Keywords
All Related Versions
Funding Information
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
- SN&N Electronics, Inc. (Research-2022-01)
This publication has 17 references indexed in Scilit:
- TianQin: a space-borne gravitational wave detectorClassical and Quantum Gravity, 2016
- The Gravity Probe B electrostatic gyroscope suspension system (GSS)Classical and Quantum Gravity, 2015
- Resonant frequency detection and adjustment method for a capacitive transducer with differential transformer bridgeReview of Scientific Instruments, 2014
- LISA technology and instrumentationClassical and Quantum Gravity, 2009
- STEP (satellite test of the equivalence principle)Advances In Space Research, 2007
- In orbit nano-g measurements, lessons for future space missionsAerospace Science and Technology, 2004
- The resolution limit of scanning capacitance microscopesJournal of Physics D: Applied Physics, 2003
- Properties of ferrites at low temperatures (invited)Journal of Applied Physics, 1997
- LISA: laser interferometer space antenna for gravitational wave measurementsClassical and Quantum Gravity, 1996
- Effects of eddy currents in transformer windingsProceedings of the Institution of Electrical Engineers, 1966