Valproic acid quantification in human serum by LC-MS/MS
Authors:
- Adriano Ronchi SpillereASAdriano Ronchi Spillere
- Laura Alencastro de AzevedoLALaura Alencastro de Azevedo
- Juliana Severo AlmeidaJAJuliana Severo Almeida
- Sarah Carobini Werner de Souza Eller Franco de OliveiraSOSarah Carobini Werner de Souza Eller Franco de Oliveira
- Tiago Franco de OliveiraTOTiago Franco de Oliveira
- Bruno Pereira dos SantosBruno Pereira dos Santos
- Simone Martins de CastroSimone Martins de Castro
Open Access
- 16 July 2026
- journal article
- Published by Universidade Federal do Rio Grande do Sul in Drug Analytical Research
- Vol. 10 (1) , 32-38
Abstract
Valproic acid (VPA) is widely used for epilepsy management, however VPA serum concentration must be monitored because its narrow therapeutic range. Some methods are used to determine the plasma or serum VPA concentration, among them immunoassay-based tests are the most used. Although immunoassays may present cross-responses with other drugs or AE metabolites, increasing the uncertainty of the method. For this reason, a liquid chromatography-mass spectrometry in tandem (LC-MS/MS) method was developed, validated and compared with particle-enhanced turbidimetric inhibition immunoassay (PETINIA). For method optimization, the protein precipitation solvent was methanol and isopropanol (3:1) and a biphenyl column (50 x 3.0 mm, 2.7 μm) was used. The method showed selectivity and specificity, and it was linear from 25 to 450 µg/mL, presenting variation coefficient lower than 8,4% and inaccuracy within 10,9%. The matrix effect was 103.9%. The VPA quantification by both methods had good correlation and the VPA assay by LC-MS/MS was 6,85% higher when compared to the immunoassay, but it still gives the same clinical stratification. The validation was successful, with easy sample preparation and appropriate selectivity, applicable for VPA therapeutic drug monitoring.Keywords
Funding Information
- Universidade Federal de Ciências da Saúde de Porto Alegre
- Universidade Federal do Rio Grande do Sul
This publication has 17 references indexed in Scilit:
- Determination of valproic acid and its six metabolites in human serum using LC–MS/MS and application to interaction with carbapenems in epileptic patientsBiomedical Chromatography, 2023
- Application of mixture design in analytical chemistryMicrochemical Journal, 2020
- Comparison ofLC‐MS/MSvs chemiluminescent microparticle immunoassay in measuring the valproic acid concentration in plasma of epilepsy patients in a new perspectiveJournal of Clinical Laboratory Analysis, 2017
- Therapeutic drug monitoring using mass spectrometry2017
- Novel LC–MS/MS method for plasma vancomycin: Comparison with immunoassays and clinical impactClinica Chimica Acta, 2015
- Evaluation of two automated immunoassays for 25-OH vitamin D: Comparison against LC–MS/MSThe Journal of Steroid Biochemistry and Molecular Biology, 2013
- Discordant carbamazepine values between two immunoassays: carbamazepine values determined by ADVIA centaur correlate better with those determined by LC-MS/MS than PETINIA assayJournal of Clinical Laboratory Analysis, 2011
- Carnitine in the treatment of valproic acid-induced toxicityClinical Toxicology, 2009
- Strategies for the Assessment of Matrix Effect in Quantitative Bioanalytical Methods Based on HPLC−MS/MSAnalytical Chemistry, 2003