Carbon monoxide poisoning mimicking long-QT induced syncope
Authors:
- A. C H De VriesAVA. C H De Vries
- A Derk Jan Ten HarkelAHA Derk Jan Ten Harkel
- 1 March 2007
- journal article
- case report
- Published by BMJ in Archives of Disease in Childhood
- Vol. 92 (3) , 244-245
Abstract
Carbon monoxide (CO)poisoning is a rare cause of QT prolongation, and is therefore easily missed. The case of a patient with unexplained syncope and QT prologation on the electrocardiogram that turned out to be related to CO poisoning is reported here. In patients with QT prolongation, uncommon causes also should be looked for.Keywords
This publication has 7 references indexed in Scilit:
- Carbon monoxide poisonings resulting from open air exposures to operating motorboats--Lake Havasu City, Arizona, 2003.2004
- Carbon monoxide poisoning − a cause of increased QT dispersionActa Anaesthesiologica Scandinavica, 2002
- Reversible increase in QT dispersion during carbon monoxide poisoningActa Anaesthesiologica Scandinavica, 2001
- Measurement, interpretation and clinical potential of QT dispersionJACC, 2000
- Dispersions of the QT Interval in Postmyocardial Infarction Patients Presenting With Ventricular Tachycardia or With Ventricular Fibrillation 11This study was supported by a grant from the Finnish Foundation for Cardiovascular Research.The American Journal of Cardiology, 1998
- Effects of Hypercapnia on Hemodynamic, Inotropic, Lusitropic, and Electrophysiologic Indices in HumansChest, 1996
- Abnormal myocardial repolarisation in response to hypoxaemia and fenoterol.Thorax, 1995