Abstract
One of the requirements for battery, fuel-cell, and photovoltaic single-phase applications is ripple-free and steady dc power during normal operation. Due to the difference in the instantaneous power at the dc and ac ports of such a single-phase power processing application, a power decoupling strategy is necessary. Conventionally, active or passive buffer circuits are used to address this issue in dc-ac converters. Under ideal conditions, the dc input current has a double-line frequency (100 Hz or 120 Hz) ripple. Thus, a buffer circuit needs to compensate and inject a suitable voltage or current to cancel this input ripple. In this regard, one of the limitations in the complete elimination of double-line frequency ripples on the dc input current is the increased capacitor voltage ripple and increased voltage stress over the circuit components. A flexible active power decoupling (FAPD) approach is introduced in this paper to increase the power range of the system over a five-level single-stage dc-ac converter. Unlike conventional APD methods, the proposed FAPD approach can effectively handle intermittent overloads without increasing the voltage stress on the power components. The impact of the proposed control method has been investigated, and the performance of the system has been verified in simulation.
Funding Information
  • Australian Research Council (Discovery Project) (DP210101382)

This publication has 10 references indexed in Scilit: