The Workplace Safety and Health Branch initiated a proactive study in the welding industry in Manitoba. Eight welding companies participated in this study. Health concerns raised by welders were welders' flash, sore/red/teary eyes, headaches, nosebleeds, and a black mucous discharge from their nasal membrane. Most welders expressed concern regarding excessive smoke levels in the workplace and inadequate ventilation. Types of welding identified were MIG mild steel, MIG stainless steel, and TIG aluminum. Monitoring involved an assessment of noise levels, fume composition, and carbon monoxide and ozone concentrations. Metal analyses were according to National Institute for Occupational Safety and Health (NIOSH) Method 7300. Noise dosimeters used were the Quest model 100 and Micro 14 & 15. Carbon monoxide was monitored using the Gastech Model 4700 and ozone using the AID Portable Ozone Meter Model 560. In Manitoba, a hearing conservation program is required when the equivalent sound exposure level (normalized Lex 8-hr)exceeds 80dBA-weighted. The American Conference of Governmental Industrial Hygienists' threshold limit valuetime weighted average (ACGIH® TLV®-TWA) for iron is 5.0 mg/m3, manganese is 0.2 mg/m3, carbon monoxide is 25 ppm, and ozone is 0.05 ppm (heavy work), 0.08 ppm (moderate work), and 0.1 ppm (light work). Welders' personal exposures to manganese ranged from 0.01-4.93 mg/m3