Plastic scintillation dosimetry: optimization of light collection efficiency
Authors:
- 23 April 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (9) , 1141-1152
Abstract
Practical contemporary radiotherapy dosimetry systems used for dose measurement and verification are ionization chambers (which typically have at least a 0.1 cm3 air cavity volume), thermoluminescent dosimeters (TLDs) and silicon diodes. However, during the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, due to their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The objectives of this study are to identify the factors preventing this new technology from realizing its full potential in commercial applications. A definition of signal to noise ratio (S/N) will be proposed for this category of detectors. In doing so the S/N ratio for an early prototype design has been calculated and/or measured. Criteria to optimize the response and sensitivity of this category of detectors are presented.Keywords
This publication has 18 references indexed in Scilit:
- A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgeryIEEE Transactions on Nuclear Science, 2001
- Radiation-induced light in optical fibers and plastic scintillators: application to brachytherapy dosimetryIEEE Transactions on Nuclear Science, 1996
- 165: Application of miniature plasctic scintillation detectors to proton therapy beam dosimetryRadiotherapy and Oncology, 1995
- Plastic scintillator dosimetry in regions with restricted secondary electron equilibriumRadiotherapy and Oncology, 1995
- A new scintillator detector system for the quality assurance of60Co and high-energy therapy machinesPhysics in Medicine & Biology, 1994
- Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetryPhysics in Medicine & Biology, 1993
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerationsPhysics in Medicine & Biology, 1992
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurementsPhysics in Medicine & Biology, 1992
- Cerenkov light generated in optical fibres and other light pipes irradiated by electron beamsPhysics in Medicine & Biology, 1992
- Ionizing Radiation Response Effects On Optical Fibers In Radiation Therapy Dosimetry Applications1989