Optical Label-Free Aptasensor Based on Weak Value Amplification for Real-Time and Ultrasensitive Detection of IgE
- 29 June 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (7) , 3625-3632
Abstract
Allergy is a prevalent disease, and the potential allergic population is expanding with industrialization and changes in people's living standards. Serum immunoglobulin E (IgE) level is one of the critical indicators for determining allergy. Here, we proposed a simple, real-time monitoring, low chip cost, label-free aptamer biosensing strategy based on weak value amplification (WVA) for the quantitative detection of IgE in serum samples, enabling early and accurate diagnosis of allergic or hypersensitive patients. The aptasensor combined an imaging weak measurement system with the high specificity of the aptamer for the marker IgE. By modifying the amino group at the 3-terminal end, the anti-IgE aptamers can attach to a dopamine-modified prism's surface and selectively recognize IgE in human serum. In the presence of IgE, a specific binding reaction occurred, resulting in a change in the refractive index of the reactive region's surface, manifested as a change in the light intensity of the camera acquired experimental images. As the concentration of IgE increased, the relative light intensity advanced sequentially. The WVA-aptasensing strategy achieved a wide detection range of 0.01 ng/mL to 2 μg/mL in phosphate buffered saline buffer, with the resolution as low as 4.3 pg/mL. IgE testing experiments in human serum have proved the feasibility of our methods in detecting complex samples. In addition, the method specifically recognized IgE without interference from other proteins. We believe that our proposed sensing strategy opens up new possibilities for ultrahigh sensitivity screening of IgE and can be expanded to detecting other biomolecules.Keywords
Funding Information
- Science and Technology Foundation of Shenzhen City (KCXFZ20201221173207022, WDZC2020200821141349001)
- Joint Research Center for Active Peptides in Flaxseed of Jilin Fuyuan Guan Food Group Co., Ltd.
This publication has 42 references indexed in Scilit:
- Biotinylated aptamer-based SPR biosensor for detection of CA125 antigenMicrochemical Journal, 2023
- Recent advancements in optical biosensors for cancer detectionBiosensors and Bioelectronics, 2022
- Paper-based upconversion fluorescence aptasensor for the quantitative detection of immunoglobulin E in human serumAnalytica Chimica Acta, 2021
- Development of peptide aptamers as alternatives for antibody in the detection of amyloid-beta 42 aggregatesAnalytical Biochemistry, 2020
- Molecular imprinting sensor based on quantum weak measurementBiosensors and Bioelectronics, 2017
- Label-free electrochemical IgE aptasensor based on covalent attachment of aptamer onto multiwalled carbon nanotubes/ionic liquid/chitosan nanocomposite modified electrodeBiosensors and Bioelectronics, 2013
- Aptasensor for amplified IgE sensing based on fluorescence quenching by graphene oxideLuminescence, 2012
- Recent trends in antibody based sensorsBiosensors and Bioelectronics, 2012
- Aptamer-based piezoelectric quartz crystal microbalance biosensor array for the quantification of IgEBiosensors and Bioelectronics, 2009
- Primary immune deficiencies with aberrant IgE productionJournal of Allergy and Clinical Immunology, 2008