Acceleration experiments for an intense H− ion beam
Authors:
- 1 December 1995
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (12) , 5412-5418
Abstract
Intense H− beams have been extracted from a large multicusp plasma source operated with cesium seeding. The H− beams were accelerated up to 100 keV by a single‐stage or a two‐stage electrode system. Spatial profiles of the beams are measured calorimetrically and the beam divergence angle is obtained from half of the e‐folding width. A minimum beam divergence angle of 5 mrads is achieved at a H− current density of 30 mA/cm2 with a beam energy of 100 keV. The ratio of acceleration current to H− current increases abruptly when a H− current saturates in the space charge limited region. This enhancement is mainly due to secondary electrons caused by the intersection of H− beams with an extraction grid. When the operating gas pressure decreases, the ratio of the acceleration current to the H− current decreases. This is related to a stripping loss of H− ions in the electrodes. A beam divergence angle reaches a minimum when a ratio of Vacc to Vext is set at an optimum value of 1.6 in the single‐stage acceleration. This ratio is almost the same as that in the double‐stage acceleration, where the optimum ratio of Eaccl/Eext is 1.5. In the optimum Eaccl/Eext ratio the divergence angle is not affected by Vacc2. The divergence angle can be reduced by changing Vacc2 even if the ratio of Eaccl/Eext is not optimized. The beam steering effect by permanent magnets buried in an extraction grid is observed in nine beamlets experiments. A simple calculation of a single particle trajectory gives a good approximation of the beam deflection angle.Keywords
This publication has 11 references indexed in Scilit:
- Improvement of the large current negative hydrogen ion source for neutral injection in the large helical deviceFusion Engineering and Design, 1995
- Large current negative hydrogen ion beam productionPhysics of Plasmas, 1994
- Experiments on the multiampere negative ion source in National Institute for Fusion ScienceReview of Scientific Instruments, 1992
- Cesium-seeded experiments on the 1/3-scaled H− ion source for large helical deviceAIP Conference Proceedings, 1992
- Development of the KEK volume H− ion sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- Cesium mixing in the multi-ampere volume H− ion sourceAIP Conference Proceedings, 1990
- A 14 cm×36 cm volume negative ion source producing multi-ampere H− ion beamsReview of Scientific Instruments, 1990
- Optimization of H− production from a small multicusp ion sourceReview of Scientific Instruments, 1989
- Multi-ampere negative hydrogen ion source for fusion applicationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1989
- Production of H− ions with addition of cesium or xenon to a hydrogen discharge in a small multicusp ion sourceJournal of Applied Physics, 1988