Radiographic Evaluation of Maxillary Sinus Lateral Wall and Posterior Superior Alveolar Artery Anatomy: A Cone‐Beam Computed Tomographic Study
- 30 May 2016
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (1) , 151-160
Abstract
Objective: The purpose of the current study is to assess the thickness of the maxillary sinus lateral wall in dentate and edentulous patients using cone beam computed tomography (CBCT). This study also provides information about the diameter, prevalence, and course of the posterior superior alveolar artery (PSAA), and its relation to the maxillary sinus floor.Materials and Methods: Four hundred and thirty CBCT scans of the maxillofacial complex (860 maxillary sinuses) were reviewed. Measurements of the lateral wall of the maxillary sinus and PSAA were performed on the CBCT images.Results: Statistical analysis showed that dental status (edentulous, non‐edentulous) of the patients had no significant effect on the lateral wall thickness. The mean thickness of the lateral wall of the maxillary sinus was 1.21 ± 1.07 mm at the second molar (M2), 1.98 ± 1.87 mm at the first molar (M1), 2.02 ± 1.53 mm at the second premolar (P2) and 2.16 ± 1.25 mm at the first premolar (P1). There was statistically significant difference between the left and right sides of the maxillary sinus only at P2 (p =.043). Detection rate of the PSAA on CBCT was reported as 60.58%. The mean diameter of the artery was 1.17 mm (range 0.4–2.8 mm). There was no significant correlation between age and the size of the PSAA. The most frequent path of the PSAA was intraosseous (69.6%), followed by intrasinusal (24.3%) and superficial (6.1%). The overall mean distance of the PSAA from the floor of the maxillary sinus is 8.16 mm.Conclusions: The results from this study suggest that using CBCT prior to the surgery provides valuable diagnostic information. However, undetected intraosseous canal in CBCT does not exclude its existence. Alteration in the lateral window design and the use of piezoelectric instruments are recommended if intraoperative complications are expected.Keywords
This publication has 35 references indexed in Scilit:
- Radiographic evaluation of the superior alveolar canal: measurements of its diameter and of its position in relation to the maxillary sinus floor: a cone beam computerized tomography studyClinical Oral Implants Research, 2013
- Location of posterior superior alveolar artery and evaluation of maxillary sinus anatomy with computerized tomography: a clinical studyClinical Oral Implants Research, 2011
- Maxillary sinus vascular anatomy and its relation to sinus lift surgeryClinical Oral Implants Research, 2010
- The Buccofacial Wall of Maxillary Sinus: An Anatomical Consideration for Sinus AugmentationClinical Implant Dentistry and Related Research, 2009
- Clinical Implications of the Topography and Distribution of the Posterior Superior Alveolar ArteryJournal of Craniofacial Surgery, 2009
- Prevalence and management of Schneiderian membrane perforations during sinus‐lift proceduresClinical Oral Implants Research, 2007
- Accuracy of measurements of mandibular anatomy in cone beam computed tomography imagesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Geometric accuracy of the NewTom 9000 Cone Beam CTDentomaxillofacial Radiology, 2005
- The Prevalence of Surgical Complications of the Sinus Graft Procedure and Their Impact on Implant SurvivalJournal of Periodontology, 2004
- The Influence of Bone Thickness on Facial Marginal Bone Response: Stage 1 Placement Through Stage 2 UncoveringAnnals of Periodontology, 2000