Mandibular Fracture Caused by Peri‐Implant Bone Loss: Report of a Case
Authors:
- Henny J.A. MeijerHMHenny J.A. Meijer
- Gerry M. RaghoebarGRGerry M. Raghoebar
- Anita VisserAVAnita Visser
- 1 July 2003
- journal article
- case report
- Published by Wiley in Journal of Periodontology
- Vol. 74 (7) , 1067-1070
Abstract
bold>Background: A major complication related to excessive bone loss around implants is fracture of the mandible. This complication is most likely to occur in a very atrophic mandible. A 57‐year‐old woman presented with progressive pain and swelling that had been present for 5 days in the right frontal region of the mandible. An intraoral radiograph revealed a radiolucency around one of the implants in the interforaminal region.Methods: Ten years earlier, 4 hollow‐screw implants of 10 mm length had been inserted in the interforaminal region of the edentulous mandible. Throughout the 10‐year postoperative period, no adverse clinical events were seen; however, during the last 7 years, no radiographic follow‐up was performed. Mobility was tested after removal of the bar, on which one of the implants appeared to be mobile. The mobile implant was removed together with the fibrous tissue.Results: At a recall visit 2 weeks later, a radiograph revealed a fracture of the mandible at the explantation site. Characteristic features of the hollow‐screw implant are the hollow body and the transverse openings in the side walls of the implant. It has been reported that these characteristic features can enhance infection and rapid bone loss, but a case of mandibular fracture has never been described.Conclusion: Radiographs should be taken on a regular and perhaps more frequent basis to diagnose excessive bone loss, so that measures can be taken to prevent the risk of mandibular fracture. J Periodontol 2003;74:1067‐1070.Keywords
This publication has 9 references indexed in Scilit:
- Implant-retained mandibular overdentures: 6-year results of a multicenter clinical trial on 3 different implant systemsJournal of Oral and Maxillofacial Surgery, 2001
- Long‐term evaluation of non‐submerged hollow cylinder implantsClinical Oral Implants Research, 2001
- Etiology and management of mandibular fractures associated with endosteal implants in the atrophic mandibleOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2000
- Clinical complications of osseointegrated implantsThe Journal of Prosthetic Dentistry, 1999
- A 5‐year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri‐implant outcome.Clinical Oral Implants Research, 1998
- Randomized prospective clinical trial of two implant systems for overdenture treatment: a comparison of the 2-year and 5-year results using the clinical implant performance scaleInternational Journal of Oral and Maxillofacial Surgery, 1998
- Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiologyEuropean Journal of Oral Sciences, 1998
- Peri‐implant mucosal aspects of ITI implants supporting overdentures. A five‐year longitudinal study.Clinical Oral Implants Research, 1994
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981