Role of Ultrasound Biomicroscopy (UBM) in the Detection and Localisation of Anterior Segment Foreign Bodies
Open Access
- 15 August 2006
- journal article
- case report
- Published by Academy of Medicine, Singapore in Annals of the Academy of Medicine, Singapore
- Vol. 35 (8) , 536-540
Abstract
Introduction: The aim of this study was to investigate the role of ultrasound biomicroscopy (UBM) in imaging anterior segment foreign bodies and compare it with conventional B-scan ultrasound and computed tomography (CT). Materials and Methods: The charts of 18 eyes with anterior segment foreign bodies were reviewed. The rates of detection of foreign bodies using ultrasound, CT scan and UBM were compared. Results: The foreign body detection rates were 36.5% by ultrasound, 88.9% by CT scan, and 94.4% by UBM. The diagnosis of presence of a foreign body using UBM was made based on high reflective echoes causing shadowing or reverberations. In 7 eyes, UBM detected injury to the zonules, guiding the operative procedure. In the 8 eyes for which all tests were performed, rates of detection of foreign bodies were 25% (2/8) with ultrasound, 87.5% (7/8) with CT, and 100% (8/8) with UBM. Conclusion: UBM is a valuable adjunct for the accurate localisation of small foreign bodies, including cilia. It offers a higher detection rate than that provided by ultrasound and CT scan. Key words: B-scan ultrasonography, Computed tomography, Ocular trauma, Retained foreign bodiesKeywords
This publication has 11 references indexed in Scilit:
- Surgical exploration minimised by ultrasound biomicroscopy localisation of intraocular foreign bodyEye, 2001
- Ultrasound biomicroscopy in the diagnosis and management of pars planitis caused by caterpillar hairsAmerican Journal of Ophthalmology, 2000
- Ultrasound biomicroscopy as a tool for detecting and localizing occult foreign bodies after ocular trauma11The authors have no financial interest in ultrasound biomicroscopy or Humphrey Instruments.Ophthalmology, 1999
- Ultrasound biomicroscopic localization and evaluation of intraocular foreign bodiesActa Ophthalmologica Scandinavica, 1998
- Ultrasound biomicroscopic detection of anterior ocular segment foreign body after traumaAmerican Journal of Ophthalmology, 1998
- A Standardized Classification of Ocular TraumaOphthalmology, 1996
- Using High-Frequency Ultrasound to Characterize Intraocular Foreign BodiesOphthalmic Surgery, Lasers and Imaging Retina, 1993
- Clinical Use of Ultrasound BiomicroscopyOphthalmology, 1991
- Limitations of Computerized Tomography in the Localization of intraocular Foreign BodiesOphthalmology, 1984
- Reliability of Ocular and Orbital Diagnosis with B-Scan UltrasoundAmerican Journal of Ophthalmology, 1972